Handleiding AlpicAir ACI-37HW1 Airconditioner

Handleiding voor je AlpicAir ACI-37HW1 Airconditioner nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 7 veelgestelde vragen, 0 comments en heeft 0 stemmen. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

Fan Coil Of Four-way Cassette Type
OWNER'S MANUAL
Thank you very much for purchasing our air conditioner,
Before using your air conditioner , please read this manual carefully and keep it for future reference.
1. IMPORTANT SAFETY INFORMATION
To prevent injury to the user or other people and property
damage, the following instructions must be followed. Incorrect
operation due to ignoring of instructions may cause harm or
damage.
WARNING
Ask your dealer for installation of the air conditioner.
Incomplete installation performed by yourself may result in a
water leakage, electric shock, and fire.
Ask your dealer for improvement, repair, and
maintenance.
Incomplete improvement, repair, and maintenance may result
in a water leakage, electric shock, and fire.
In order to avoid electric shock, fire or injury, or if you
detect any abnormality such as smell of fire, turn off the
power supply and call your dealer for instructions.
Never let the indoor unit or the remote controller get wet.
It may cause an electric shock or a fire.
Never press the button of the remote controller with a
hard, pointed object.
The remote controller may be damaged.
Never replace a fuse with that of wrong rated current or
other wires when a fuse blows out.
Use of wire or copper wire may cause the unit to break down
or cause a fire.
It is not good for your health to expose your body to the
air flow for a long time.
Do not insert fingers, rods or other objects into the air
inlet or outlet.
When the fan is rotating at high speed, it will cause injury.
Never use a flammable spray such as hair spray,
lacqueror paint near the unit.
It may cause a fire.
Never touch the air outlet or the horizontal blades while
the swing flap is in operation.
Fingers may become caught or the unit may break down.
Never put any objects into the air inlet or outlet.
Objects touching the fan at high speed can be dangerous.
Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.
Do not dispose this product as unsorted municipal
waste.Collection of such waste separately for special
treatment is necessar
CAUTION
Do not use the air conditioner for other purposes.
In order to avoid any quality deterioration, do not use the unit
for cooling precision instruments, food, plants, animals or
works of art.
Before cleaning, be sure to stop the operation, turn the
breaker off or pull out the supply cord.
Otherwise, an electric shock and injury may result.
In order to avoid electric shock or fire, make sure that an
earth leak detector is installed.
Be sure the air conditioner is grounded.
In order to avoid electric shock, make sure that the unit is
grounded and that the earth wire is not connected to gas or
water pipe, lightning conductor or telephone earth wire.
Do not operate the air conditioner with a wet hand.
An electric shock may happen.
Do not touch the heat exchanger fins.
These fins are sharp and could result in cutting injuries.
Do not place items which might be damaged by moisture
under the indoor unit.
Condensation may form if the humidity is above 80%, the
drain outlet is blocked or the filter is polluted.
After a long use, check the unit stand and fitting for
damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deficiency, ventilate the room
sufficiently if equipment with burner is used together
with the air conditioner.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air flow.
Adverse influence to little children, animals and plants may
result.
1
owner's manual
To prevent water leak, contact your dealer.
When the system is installed and runs in a small room, it is
required to keep the concentration of the water, if by any
chance coming out, below the limit. the cool capacity would
be lower.
Turn off any combustible heating devices, ventilate the
room, and contact the dealer where you purchased the
unit.
Do not use the air conditioner until a service person confirms
that the portion where the water leaks is repaired.
W ARNING
The safty precautions listed here are divided into two categories. In
either case, important safty information is listed which must be read
carefull y .
Failure to observe a warning may result in death.
CAUTION
Failure to observe a caution may result in injury or damage
to the equipment.
Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under the
indoor unit.
It may cause incomplete combuston or deformation of the unit
due to the heat.
Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.
The appliance should not be used by children without
supervision.
2. PARTS NAMES
The air conditioner consists of the indoor unit, the outdoor unit,
the connecting pipe and the remote controller.
This function is used to operate the unit temporarily in case you
misplace the remote controller or its batteries are exhausted.
Two modes including AUTO and FORCED COOL can be
selected through the TEMPORARY BUTTON on the air-in grill
control box of the indoor unit. Once you push this button, the air
conditioner will run in such order: AUTO, FORCED COOL,
OFF, and back to AUTO.
AUTO
The OPERATION lamp is lit, and the air conditioner will run
under AUTO mode. The remote controller operation is enabled
to operate according to the received signal.
FORCED COOL
The OPERATION lamp flashes, the air conditioner will turn to
AUTO after it is enforced to cool with a wind speed of HIGH for
30 minutes. The remote controller operation is disabled.
OFF
The OPERATION lamp goes off. The air conditioner is OFF
while the remote controller operation is enabled.
1
2
3
3. OPERATION RANGE
Use the system in the following temperature for safe and
effective operation.
NOTE
1
2
3
If air conditioner is used outside the above conditions, it
may cause the unit to function abnormally.
The phenomenon is normal that the surface of air
conditioning may condense water when the relative
larger humidity in room, please close the door and
window.
Optimum performance will be achieved within these
operating temperature range.
In heating mode,the temperature of the inlet water must
be under 75℃.
Water system operating pressuer: Max: 1.6MPa, Min:
0.15MPa.
4. HINTS FOR ECONOMICAL OPERATION
The following should be noticed to ensure an economical
operation.
Adjust the air flow louver properly and avoid direct air flow to
room inhabitants.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Prevent direct sunlight during cooling operation by using
curtains or blinds.
Ventilate often. Extended use requires special attention to
ventilation.
Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease
in the cooling or heating effect.
Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop the operation.
Set the timer .
If you don't plan to use the unit for a long time, please take the
batteries from the remote controller. When the power is on,
some energy will be consumed,even if the air conditioner isn't in
operation. So please disconnect the power to save energy.
2
owner's manual
Function indicators on indoor unit display panel
(figure 1) Display panel
NOTE
This manual does not include Remote Controller
Operations, see the<<Remote Controller Owner's
manual>> packed with the unit for details.
PRE-DEF indicator(cooling and heating type)
or fan only indicator(cooling only type)
Infrared signal receiver
Operation lamp Timer indicator
Alarm indicator
Temporary button
OPERATION TIMER DEF./FAN ALARM
Frost indicator
5
If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get
into the food chain, damaging your health and well-being
DISPOSALDo not dispose this product as unsor-
ted municipal waste. Collection of such waste sepa-
rately for special treatment is necessary.
Do not dispose of electrical appliances as unsorted municipal
waste, use separate collection facilities.
Contact you local government for information regarding the
collection systems available.
Cooling operation
Heating operating
(cooling only
type without)
Mode
Temperature
Outdoor
temperature
Room
temperature
water inlet
temperature
0°C30°C
17°C32°C
30°C75°C
3°C20°C
-15°C24°C
0°C43°C
Keep the indoor unit and remote controller at least 1 m away
from televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.
A dirty air filter will reduce cooling or heating efficiency, please
clean it once two weeks.
5. ADJUSTING AIR FLOW DIRECTION
6. MAINTENANCE
While the unit is in operation, you can adjust the air flow louver
to change the flow direction and naturalize the room
temperature evenly. Thus you can enjoy it more comfortably.
Set the air flow direction.
Press the SWING button to adjust the louver to the desired
position and press this button again to maintain the louver at
this position.
Adjust the air flow direction automatically.
Press the SWING button, the louver will swing automatically.
While this function is set, the swing fan of indoor unit runs;
otherwise, the swing fan doesn't run. The swing scale of every
side is 30. When the air conditioner isn't in operation (including
when TIMER ON is set), the SWING button will be invalid.
CAUTION
Before you clean the air conditioner, be sure the power
supply is off.
Maintenance after a long stop period
(eg. at the beginning of the season)
Maintenance before a long stop period
(eg. at the end of the season)
Check and remove everything that might be blocking inlet
and outlet vents of indoor units .
Clean air filters and casings of indoor units.
Refer to "Cleaning the air filter" for details on how to proceed
and make sure to install cleaned air filters back in the same
position.
Turn on the power at least 12 hours before operating the unit
in order to ensure smoother operation. As soon as the power
is turned on, the remote controller displays appear.
Let the indoor units run in fan only operation for about half a
day in order to dry the interior of the units.
Clean air filters and casings of indoor units. Refer to "
Cleaning the air filter" for details on how to proceed and
make sure to install cleaned air filters back in the same
position.
Cleaning the air filter
The air filter can prevent the dust or other particulate from
going inside .In case of blockage of the filter , the working
efficiency of the air conditioner may greatly decrease .
Therefore , the filter must be cleaned once two weeks during
long time usage.
If the air conditioner is installed in a dust place , clean the the
air filter frequent.
If the accumulated dust is too heavy to be cleaned , please
replace the filter with a new one(replaceable air filter is an
optional fitting).
Open the air-in grill
Push the grill switches towards the middle simultaneously as
indicated in figure 3. Then pull down the air-in grill.
The control box cables ,which are originally connected with
the main body electrical terminators must be pulled off before
doing as indicated above.
1
2
3
4
Take out the air-in grill (together with the air filter shown in
figure 4).
Pull the air-in grill down at 45 and lift it up to take out the
grill.
Dismantle the air filter.
Clean the air filter
Vacuum cleaner or pure water may be used to clean the air
filter.If the dust accumulation is too heavy , please use soft
brush and mild detergent to clean it and dry out in cool place
.
The air-in side should face up when using vacuum cleaner.
(See Fig. 5)
The air-in side should face down when using water.
(See Fig. 6)
Caution : Do not dry out the air filter under direct
sunshine or with fire.
3
owner's manual
ADJUST IT UP AND DOWN
(figure 2)
Check if the wiring is not broken off or disconnected.
Disconnect the power supply before cleaning and
maintenance. Use dry cloth to clean the unit.
A wet cloth may be used to clean the indoor unit if it is very
dirty.
Never use a damp cloth on the remote controller.
Do not use a chemically-treted duster for wiping or leave such
material on the unit for long.
it may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar
solvents for cleaning.
These may cause the plastic surface to crack or deform.
Re-install the air filter.
Install and close the air-in grill in the reverse order of step 1
and 2 and connect the control box cables to the
corresponding terminators of the main body .
5
6
W
h
e
n
fig.3
fig.4
fig.5
fig.6
7. FOLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES
Symptom 1: The system does not operate
Symptom 2: Change into the fan mode during cooling
mode
Symptom 3: White mist comes out of a unit
Symptom 4: Noise of air conditioners cooling
The air conditioner does not start immediately after the ON/OFF
button on the romote controller is pressed.
If the operation lamp does not lights, the system is in abnormal
condition. or there is no problem with the unit.
If the operation lamp and the "
PRE-DEF indicator(cooling and
heating type) or fan only indicator(cooling only type)"
light, it
means you choose the heating model, When just starting, the
indoor unit appears "anti cold wind" protection because of its
overlow outlet temperature.
When the room temperature drops to the set temperature, the
indoor unit changes to fan mode; when the temperature rises
up, the rotate speed of the fan will rise too, It is same in the
heating mode.
Symptom 4.1: Indoor unit
When humidity is high during cooling operation If the interior of
an indoor unit is extremely contaminated, the temperature
distribution inside a room becomes uneven. It is necessary to
clean the interior of the indoor unit. Ask your dealer for details
on cleaning the unit. This operation requires a qualified service
person.
A continuous low "shah" sound is heard when the system is in
cooling operation or at a stop.
When the drain pump (optional accessories) is in operation,this
noise is heard.
A "pishi-pishi" squeaking sound is heard when the system stops
after heating operation.
Expansion and contraction of plastic parts caused by
temperature change make this noise.
Symptom 4.2: Indoor unit, outdoor unit
A continuous low hissing sound is heard when the system is in
operation.
This is the sound of water flowing through both indoor and
outdoor units.
A hissing sound which is heard at the start or immediately after
stopping operation .
This is the noise of water caused by flow stop or flow change.
4
owner's manual
Solution
Clean the heat exchanger.
Clean the air filter.
Eliminate all dirties and make air
smooth.
Close doors and windows.
Make curtains in order to shelter from
sunshine.
Reduce heat source.
AC cooling capacity reduces (normal).
Check leakage .
Symptoms Causes
Symptom 5: Dust comes out of the unit
Symptom 6: The units can give off odours
When the unit is used for the first time in a long time.
This is because dust has gotten into the unit.
The unit can absorb the smell of rooms, furniture, cigarettes,
etc., and then emit it again.
The operation lamp is flashing rapidly (five times per second),
you disconnect the unit with the power and then connect the
unit with the power again after two or three minutes but the
lamps still flash.
Switch operations are erratic.
The fuse is blown frequently or the circuit breaker is tripped
frequently.
Foreign matter or water has fallen inside the air conditioner.
Water leaks from the indoor unit.
8. TROUBLESHOOTING
If one of the following malfunctions occur, stop operation, shut
off the power, and contact with your dealer.
If the system does not properly operate except the above
mentioned cases or the above mentioned malfunctions is
evident, investigate the system according to the following
procedures. (see in table 1)
8.1. Troubles and causes of air conditioner
Unit does not start
Air flowing normally but
completely can't cooling
Units start or stop frequently
Low cooling effect
Low heating effect
Power failure.
Power switch is off.
Fuse of power switch may have burned.
Batteries of remote controller exhausted
or other problem of controller.
Temperature is not setted correctly.
Air or no concreting gas in the watering
circuit.
three-way valve is malfunction.
Voltage is too high or too low.
System circuit is blocked.
Temperature is not setted correctly.
Indoor unit heat exchanger is dirty.
The air filter is dirty.
Inlet/outlet of indoor units is blocked.
Doors and windows are open
Sunlight directly shine.
Too much heat resource.
Leakage of water .
Wait for the comeback of power.
Switch on the power.
Replace the fuse.
Replace the batteries or check the
controller.
Set the temperature properly.
Vacuum .
Maintenance or change three-way
valve.
Install manostat.
Find reasons and solution.
Use heating device.
Close doors and windows.
Check leakage.
Doors and windows not completely
closed.
Leakage of water.
table 1
5
owner's manual
8.2 Troubles and causes of remote controller
Before asking for serving or repairing , check the following
points.
(see in table 2)
6
owner's manual
Symptoms
Causes
The fan speed can not be
changed.
Check whether the MODE
indicated on the display is
"AUTO"
Check whether the MODE
indicated on the display is
"DRY"
When the automatic mode is
selected, the air conditioner will
automatically change the fan
speed.
When dry operation is selected,
the air conditioner automatically
change the fan speed. The fan
speed can be selected during
"COOL" , "FAN ONLY",
and
"HEAT"
The remote controller signal is
not transmitted even when
the ON/OFF button is pushed.
Check whether the batteries
in the remote controller are
exhausted.
The power supply is off.
No receiving tone sounds
from the indoor unit even
when the ON/OFF button is
pressed.
Check whether the signal
transmitter of the remote
controller is properly directed
to the infrared signal receiver
of the indoor unit when the
ON/OFF button is pressed.
Directly transmit the signal transmitter of
the remote controller to the
infrared signal receiver of the
indoor unit, and then repeatly
push the ON/OFF button twice.
The indication on the display
disappears after a lapse of
time.
Check whether the timer
operation has come to an
end when the TIMER OFF
is indicated on the display.
The air conditioner operation will
stop up to the set time
The TIMER ON indicator
goes off after a lapse of
certain time.
Check whether the timer
operation is started when
the TIMER ON is indicated
on the display.
Up to the set time, the
air conditioner will automatically
start and the appropriate
indicator will go off.
The TEMP. indicator does
not come on.
Check whether the MODE
indicated on the display is
FAN ONLY
The temperature cannot be set during
FAN mode.
table 2
Solution
×
NO.
Malfunction running lamp timer lamp defrosting lamp alarm lamp
alarm lamp
1
2
3
4
Room temperature sensor
checking channel is abnormal
Evaporator sensor checking
channel is abnormal
EEPROM malfunction
Water-level switch
malfunction
×
×
×
×
×
×
×
×
×
Extinguish,☆ Flash at 5Hz
E2
E3
E7
EE
8.3 Malfunctions and malfunction code
If anything happens like the situation described below, please shut off the power supply of the unit
and contact with the custormer service center immediately.
5
Fan Failure
×
×
E8
6
Not set models
× ×
PH
×
2020001A1954 V1.3
此页不做菲林
1.按CE认证要求增加相关内容,更改第1.2.3.8.9页内容
由V1.0升级到V1.1
双胶纸100克,小A4
V1.2更改说明如下:
封面商标颜色改为黑色。
V1.3更改说明如下:
修改第6页,完善风盘故障代码
Download de handleiding in het Nederlands en/of Engels (PDF, 1.14 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de AlpicAir ACI-37HW1 Airconditioner vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de AlpicAir ACI-37HW1 Airconditioner?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de AlpicAir ACI-37HW1 Airconditioner. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je AlpicAir ACI-37HW1 Airconditioner. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met AlpicAir. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van AlpicAir ACI-37HW1 Airconditioner in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk AlpicAir
Model ACI-37HW1
Categorie Airconditioners
Bestandstype PDF
Bestandsgrootte 1.14 MB

Alle handleidingen voor AlpicAir Airconditioners
Meer handleidingen voor Airconditioners

Veelgestelde vragen over AlpicAir ACI-37HW1 Airconditioner

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Hoe vaak moet ik de filters van mijn airconditioner vervangen of schoonmaken? Geverifieerd

Het is aan te raden de filters van de airconditioner 4 keer per jaar te controleren. Vervuilde filters kunnen met een stofzuiger uitgezogen worden of, afhankelijk van het type, gewassen worden. Tijdens jaarlijks onderhoud dient een professional te bepalen of de filters aan vervanging toe zijn.

Ik vind dit nuttig (2675) Lees meer

Waar staat BTU voor? Geverifieerd

BTU staat voor British Thermal Unit. Dit is een eenheid voor koelend vermogen.

Ik vind dit nuttig (944) Lees meer

Werkt elke airconditioner ook als luchtontvochtiger? Geverifieerd

De koude lucht die uit een airconditioner komt heeft vaak een vrij lage luchtvochtigheid. Toch is het effect minder dan bij het gebruik van een daadwerkelijke luchtontvochtiger. Sommige airconditioners hebben wel een speciale functie om de lucht te ontvochtigen.

Ik vind dit nuttig (701) Lees meer

Wat is R-410A? Geverifieerd

R-410A is een koelmiddel dat wordt gebruikt in apparaten die koelen tot 0°C, zoals koelkasten en airconditioners. Het is de vervanger van oudere koelmiddelen en brengt geen schade toe aan de ozonlaag.

Ik vind dit nuttig (474) Lees meer

Kan ik mijn mobiele airconditioner in een kastje plaatsen om hem uit zicht te houden? Geverifieerd

Nee, absoluut niet. Een mobiele airconditioner heeft ruimte nodig voor de aanvoer en afvoer van verse lucht. In een te kleine ruimte kan het apparaat oververhitten.

Ik vind dit nuttig (345) Lees meer

Wat is de beste plaats om de binnenunit van een split-type airconditioner te plaatsen? Geverifieerd

Dit hangt af van de ruimte, maar over het algemeen kunnen de volgende regels aangehouden worden. Zorg dat de verspreiding van lucht niet belemmerd wordt. Zorg dat de plek toegankelijk is voor onderhoud. Zorg dat de unit op minimaal 2 meter hoogte geplaatst wordt.

Ik vind dit nuttig (345) Lees meer

Heeft een airconditioner een negatieve invloed op de luchtkwaliteit? Geverifieerd

Als de airconditioner goed is onderhouden dan heeft deze geen invloed op de luchtkwaliteit. Als echter bijvoorbeeld een filter lang niet is vervangen of andere vormen van onderhoud niet worden uitgevoerd, dan kan een airconditioner vieze lucht produceren.

Ik vind dit nuttig (340) Lees meer
Handleiding AlpicAir ACI-37HW1 Airconditioner

Gerelateerde producten

Gerelateerde categorieën