Handleiding voor je APC P6GC Overspanningsbeveiliging nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 0 veelgestelde vragen, 0 comments en heeft 0 stemmen. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

07/2009990-3645
User Guide - Essential SurgeArrest
®
Surge Protector with LCD Timer P4GC/P6GC
Complete and return the warranty card.
Read the safety instructions before installing the unit. Failure to follow these instructions may cause damage to
equipment.
The SurgeArrest is intended for indoor use only. The internal components are not sealed from the environment.
Do not install the SurgeArrest where there is excessive heat or humidity.
Do not use extension cords with the SurgeArrest.
Plug the SurgeArrest into a three wire, grounded receptacle only. If the Building Wiring Fault LED illuminates indicating a wiring
fault, discontinue use and have a qualified electrician check the building wiring for an overloaded neutral, reversed polarity, or a
missing ground.
Never install electrical wiring during a lightening storm.
Overview and Operation
This unit enables the user to specify the time that all outlets controlled by the timer (for outlets on the P4GC and 5 outlets on the P6GC),
will turn on and off. Specific times of day and specific days of the week can be selected. See “LCD Timer” on page 2.
When unplugged from the wall outlet the unit will shut off in 20 seconds. Programmed settings will be held in memory for future use.
LCD Timer Display-The LCD timer display shows the settings selected using the the buttons described in this guide.
R (reset)-Push this button to clear all settings and reset the unit to the factory default state.
ON/OFF switch P6GC models only-This switch provides on/off power control to all of the outlets. To disconnect power to the
outlets on P4GC models, unplug the unit from the wall outlet. See “LCD Timer” on page 2.
TIME/OVERRIDE button-Use Time to set and display the current day and time. Use OVERRIDE as an on/off button for the
current program. OVERRIDE acts as a circuit breaker in output overload conditions. See “LCD Timer” on page 2.
CONTROLLED by TIMER outlets-P6GC models, five outlets are controlled by the timer. P4GC models, all four outlets are
controlled by the timer.
PROTECTION WORKING LED-This LED illuminates during normal operation of the CONTROLLED by MASTER outlets.
The LED will extinguish if a sustained high-energy power surge as with a lightening strike, causes the circuit breaker to trip. Disconnect
all equipment from the SurgeArrest before pushing the circuit breaker Reset button. If the LED does not illuminate after the circuit
breaker is reset and the Auto/Manual switch is switched to Auto, contact APC using the contact information provided in this guide.
BUILDING WIRING FAULT LED-This LED illuminates when there is no ground circuit, or there is a reversed polarity in the
building wiring. Discontinue use and have a qualified electrician check the wiring in the building
TIMER ENABLED-This LED illuminates when the LCD TIMER function is enabled. See “LCD Timer” on page 2.
P4GC P6GC
PROTECTION WORKING
BUILDING
WIRING FAULT
TIMER ENABLED
srg006a
CONTROLLED BY MASTER
PROTECTION
WORKING
BUILDING
WIRING FAULT
TIMER ENABLED
Download de handleiding in het Nederlands en/of Engels (PDF, 0.06 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de APC P6GC Overspanningsbeveiliging vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de APC P6GC Overspanningsbeveiliging?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de APC P6GC Overspanningsbeveiliging. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je APC P6GC Overspanningsbeveiliging. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met APC. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van APC P6GC Overspanningsbeveiliging in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk APC
Model P6GC
Categorie Overspanningsbeveiliging
Bestandstype PDF
Bestandsgrootte 0.06 MB

Alle handleidingen voor APC Overspanningsbeveiliging
Meer handleidingen voor Overspanningsbeveiliging

Handleiding APC P6GC Overspanningsbeveiliging

Gerelateerde producten

Gerelateerde categorieën