Example - your most
fertile days may vary
from cycle to cycle
16
14 15131098765
Your 2 most
fertile days
Day of cycle
LH surge
Start daily tests
LH level
1211
No LH surge
LH surge
1
3
4
5
6
6
2
When you are ready to test…
• Remove the test stick from the foil
wrapper. Use the test stick straight
away.
• Before applying urine to the test stick it
must be inserted into the test holder.
Follow the steps below.
Eject button
Test holder
Display
Assemble the test
• Find the pink arrow on the test holder.
• Line up both pink arrows.
• Insert the test stick into the test holder until it clicks into
place and the test ready symbol appears.
• Do not use until the test ready symbol appears.
• When the test ready symbol appears, do the test straight away.
• If the test ready symbol does not appear, OR if the symbol has
disappeared, eject the test stick and re-insert it carefully.
• If the symbol still does not appear refer to Q17 overleaf.
Do the test
With the test ready symbol showing
on the display…
• Either test directly in your urine
stream.
• Place just the absorbent tip,
pointing downward in your urine
stream for 5-7 seconds.
• Take care not to get the test holder
wet.
• Or test a sample of your
urine collected in a
clean, dry container.
• Dip just the absorbent
tip in your collected
urine sample for
15 seconds.
Remove the cap
• Find the pink arrow on the
test stick.
Wait
• Keep the absorbent tip pointing downwards or lay the test flat. Throughout
testing never hold the test with the absorbent tip pointing upwards.
• The test ready symbol will start flashing after 20-40 seconds to show the
test is working.
• DO NOT EJECT THE TEST STICK.
• Replace the cap then wipe o any excess urine.
• If the test ready symbol does not start flashing, refer to Q5 overleaf.
Read your result
• Within 3 minutes the
display will show
your result.
• If your result is you have detected your
LH surge and have reached your most fertile
time. Make love at any time during the next
48 hours to maximise your chance of
becoming pregnant. There is no need to
carry on testing during this cycle.
Test holder
Test stick
Absorbent tip
Absorbent
tip
• If your result is you
have not detected your
LH surge. Test again
tomorrow at the same
time using a new test
stick.
Test stick
Cap
Pink arrow
Test stick
Test stick
Test holder
When to start testing
The day the LH surge occurs varies from woman to woman and from one cycle to another. To have the best chance of
detecting your LH surge, you need to know your usual cycle length. The day your period starts (first day of full bleeding) is
Day 1. Your cycle length is the total number of days from Day 1 up to and including the day before your next period starts.
If you do not know your usual cycle length or your cycle length varies, refer to Q1 overleaf.
Use the table below to work out the day you should start testing. You can test any time of the day, but it should be at about
the same time each day (many women find it most convenient first thing in the morning). It’s important to drink normally
and not to urinate for 4 hours before testing.
How Clearblue Digital Ovulation Test works with you
Clearblue Digital works by detecting the increase (surge) in a hormone
called luteinising hormone (LH) in your urine. The LH surge occurs
approximately 24-36 hours prior to the release of an egg from your
ovaries – a process known as ovulation. You are at your most fertile on
the day your LH surge is detected and the day after.
Your 2 most fertile days begin from the time that Clearblue Digital
detects your LH surge. Make love at any time during the following
48 hours to maximise your chance of becoming pregnant.
Before applying urine to the test stick it must be inserted into the test holder.
Please read this leaflet carefully before doing a test.
OR
Error A
• You have ejected the test stick too soon.
Re-insert the test stick into the test holder
immediately. Refer to Q14 overleaf.
Error A
• You have ejected the test stick too soon.
Re-insert the test stick into the test holder
immediately. Refer to Q14 overleaf.
Error B
• Refer to Q15
overleaf.
Error B
• Refer to Q15
overleaf.
Error C
• Refer to Q16
overleaf.
Error C
• Refer to Q16
overleaf.
Error symbols
5-7
seconds
15
seconds
T
e
s
t
r
e
a
d
y
“
C
l
i
c
k
”
Length of your cycle (days) 04 93 83 73 63 53 43 33 23 13 03 92 82 72 62 52 42 32 22
5 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Count the first day of your period as day 1, start
testing on the day shown under your cycle length
Refer to
Q2 overleaf
• Once you have read your result you MUST press the eject button and remove
the test stick.
• The result of your test can only be read on the test holder display.
• You cannot read your result from any lines that you see on the test stick.
• Your result will remain on the display for 8 minutes.
• If your test stick is still inserted and the
display is now blank, eject the test stick and
your result will re-appear for 2 minutes.
• Do not re-insert a used test stick.
English
Digital
Ovulation Test
41 or more
21 or less
Praat mee over dit product
Laat hier weten wat jij vindt van de Clearblue Digital Ovulatietest. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.