Once a Fibaro Smoke Sensor has reported low battery level or battery is
discharged, it should be replaced observing the following procedure:
1) Detach the sensor from its cover by turning the device counter-clockwise.
2) Remove the flat battery from the device. Then press and hold the B-button for
3 seconds.
3) Insert a new CR123A battery observing the polarities shown inside. Visual
indicator will signal Z-Wave network inclusion status (green - device included,
red - device not included).
4) Test Fibaro Smoke Sensor’s operation by performing a self-test (see p. VI).
5) Attach the device into the cover by turning clockwise.
ENG
OPERATING MANUAL
SMOKE SENSOR
FGSD-002-EN-A-v1.01
The Fibaro Smoke Sensor is a universal, optical Z-Wave smoke detector. Fire
alarm is signaled by sound, visual indicator blinking and by sending Z-Wave alarm
and control commands.
The optical sensor detects smoke at an early stage of fire, often before flames
appear and temperature starts to rise significantly. Moreover the device has a
built-in temperature sensor, which is programmable indicator of exceeding set
temperature level.
The Fibaro Smoke Sensor is designed to be placed on a wall or ceiling. Visual
indicator signals fire, operating mode and is used to see if device is within the
Z-Wave network. The smoke sensor is designed to operate in confined spaces,
under normal conditions (lacking smoke, dust, condensed water vapor).
SPECIFICATIONS
Battery Type:
Compliance with:
Radio protocol:
Radio frequency:
Range:
Operational Temperature:
Operational Humidity:
Measured Temperature Range:
Temperature Measuring Accuracy:
Dimensions (Diameter x Height):
CR123A
EN 14604:2005
Z-Wave
868,4 or 869,8 MHz EU;
908,4 or 916 MHz US;
921,4 or 919,8 MHz ANZ;
869 MHz RU;
up to 50m outdoors
up to 30m indoors
(depending on terrain and building
structure)
0
o
C - 55
o
C
0% - 93%
-20
o
C to 100
o
C
0,5
o
C (within 0
o
C - 55
o
C range)
65 x 28 mm
TECHNICAL INFORMATION
• Compatible with any Z-Wave or Z-Wave+ Controller
• Supports protected mode (Z-Wave network security mode) with
AES-128 encryption
• Extremely easy installation - simply install it in location prone to fire.
• Battery powered
• 3 levels of sensors sensitivity
• Built-in casing opening detector
• Alarm is signaled by sound, visual indicator and Z-Wave control command
• Programmable excess temperature warning
• Automatic test performed every 10 seconds
I. ADDING TO Z-WAVE NETWORK
III. SENSOR INSTALLATION
Fig. 1 - Fibaro Smoke Sensor top view
BATTERY TIPS
Fibaro Smoke Sensor’s battery life is at least equal to two years.
The wake-up interval is recommended to be set at a default value
(6 hours). In case of choosing a smaller value, the lifetime of a
battery can decrease significantly.
The current battery level is displayed in the Z-Wave controller’s
interface, e.g. Home Center 2 or Home Center Lite. Red battery
icon means that battery needs replacement. In addition, the device
itself, apart from the main controller, monitors the battery level and
a low battery is signaled with a yellow blinking visual indicator and
an intermittent sound alarm. The Fibaro Smoke Sensor reports
low battery level for at least 30 days until it is completely
discharged.
i
CAUTION
When handled carelessly or used in non-specified environment
conditions, the device may not function properly. It’s highly
recommended to take all safety precautions to ensure safety and
property protection.
CAUTION
Depending on the Smoke Sensors internal conditions (e.g. battery
discharge, device failure, etc.) and ambient conditions, fire alarms
are not always effective in all situations. Smoke Sensors must be
tested regularly according to this operating manual and local code.
Ventilation systems, chimneys and potentially dangerous devices
that can cause a fire should be regularly inspected as well.
There are various situations against which the fire alarm may not
be effective, for example:
1) Fires where the victim is intimate with a flaming initiated fire; for
example, when a person’s clothes catch fire while cooking;
2) Fires where the smoke is prevented from reaching the detector
due to a closed door or other obstruction;
3) Incendiary fires where the fire grows so rapidly that an
occupant’s egress is blocked even with properly located
detectors.
Fibaro Smoke Sensor inclusion:
1) Install the battery. Visual indicator will signal the Z-Wave network inclusion status
(red - device ready for inclusion, green - device included, remove firstly - see p. II).
2) Make sure the device is located within direct range of the Z-Wave controller.
3) Set the main controller into the learning mode (see main controller’s operating
manual).
4) Quickly, triple click the B-button, located on Fibaro Smoke Sensor’s casing.
5) Fibaro Smoke Sensor will be detected and included in the Z-Wave network.
II. REMOVING FROM Z-WAVE NETWORK
1) Make sure the sensor is connected to battery.
2) Set the main controller into the learning mode (see main controller’s operating
manual)
3) Quickly, triple click the B-button, located on Fibaro Smoke Sensor’s casing.
!
!
NOTE
It’s recommended to install the sensor on the ceiling or upper
portion of wall at least 40cm (2 feet) from corners and other
objects. Particular attention should be paid to any adjacent objects
or devices which can impede smoke’s access to the sensor. It’s
recommended to install Fibaro Smoke Sensor in all rooms prone
to fire, and in between such rooms as well.
i
INSTALLATION NOTES:
1) When choosing location of smoke sensor, make sure the alarm sound can be
easily audible in other rooms in the building.
2) It’s recommended to install the sensor in already decorated, painted rooms.
3) It’s recommended to install the sensor at least 1,5m from air conditioners.
4) Do not install the sensor in direct sunlight. Keep at least 0,5m distance from
light sources.
5) Do not install the sensor in places prone to drafts.
6) Do not install the sensor in places with high water vapor condensation, e.g.
above stoves, ovens, kettles, etc.
7) The device can not be installed in places where the temperature exceeds
operational values (0
o
C - 55
o
C).
IV. FIRE DETECTION
Fibaro Smoke Sensor responds to the physical presence of smoke. Smoke
presence is required for the device to react. Fibaro Smoke Sensor every 10
seconds checks for smoke presence. Once the level of smoke exceeds value set
in parameter 1, Fibaro Smoke Sensor triggers an alarm.
Fire alarm is signaled by sending an appropriate alarm command to devices, the
Z-Wave controller and also by an intermittent sound and visual indicator blinking
red. Once the fire alarm has ceased, the sensor checks whether the smoke has
actually disappeared before getting back to normal operation, i.e. performing a self
test each 10 seconds and checking for presence of smoke.
NOTE
As described in section IV, the Fibaro Smoke Sensor checks for
smoke presence every 10 seconds. In addition, the device checks
for malfunction and tests the Z-Wave network communication (see
section VII) at each wake up interval (6 hours by default) and when
sending reports, provided that range test has been enabled in
advanced configuration.
CAUTION
Fibaro Smoke Sensor is a multiple use device, however, for
greater safety, it’s recommended to replace the device with a new
one after a fire occurrence.
!
i
V. PROGRAMMABLE EXCESS TEMPERATURE WARNING
Apart from detecting presence of smoke, Fibaro Smoke Sensor has an additional
function of informing of exceeding the programmed temperature threshold. The
function is disabled by default in parameter 2 settings. Excess temperature
warning is defined by user in parameter 30 - set to 55ºC by default. Excess
temperature level can be also signaled by visual indicator glow (parameter 3) and
short beep (parameter 4). Parameter 20 should not be set to 0 because such
setting disables temperature measurements.
VII. DETECTING LACK OF Z-WAVE RANGE
When included in the Z-Wave network, Fibaro Smoke Sensor tests the network
communication. By default the procedure is performed at each temperature report
depending on parameters 20 and 21 settings. In addition, Z-Wave network communica-
tion test is performed during waking up. Lack of the Z-Wave network communication may
be signaled by an intermittent alarm sound and visual indicator blinking violet. By default
sound and visual signals are disabled but you can enable it by changing values of
parameters 3 and 4 (section XVI).
Once a Fibaro Smoke Sensor has reported no Z-Wave network communication, it’s
recommended to wake up the device by clicking the B-button. If it doesn’t stop the alarm,
Z-Wave networks operation and the main controllers operation need to be verified.
The Fibaro Smoke Sensor will cancel the Z-Wave network communication alarm once it
communicates with the network after manual or automatic wake up.
Fig. 2 - Fibaro Smoke Sensor bottom view
without the battery installed
B - BUTTON AND
VISUAL NDICATOR
Installing Fibaro Smoke Sensor:
1) Include the device into the Z-Wave network (see p. I). Note the inclusion process
may be performed ONLY in direct range of the main controller.
2) Install the sensor’s cover in desired location.
3) Screw the Fibaro Smoke Sensor into the cover.
4) If the sensor is already included into the Z-Wave network, wake it up
by clicking the B-button. Otherwise, add the device as described in p. I.
5) Test Fibaro Smoke Sensor’s operation by performing a self-test - press & hold
the B-button (see p.VI)
6) Test the Z-Wave network range (see p.XIV) assuring the device is within range.
CAUTION
Current studies show that fire alarms may not awake all sleeping
individuals and that it is the responsibility of other residents to
assist those who may not be awakened by the alarm sound or
those who may be incapable of safely leaving the area unassisted.
!
CAUTION
Read this manual before attempting to install the device. Failure to
observe recommendations included in this manual may be
dangerous or cause a violation of the law. The manufacturer,
Fibar Group Sp. z o.o., will not be held responsible for any loss or
damage resulting from not following the instructions of operating
manual.
CAUTION
Work within local code height requirements during installation of
the Fibaro Smoke Sensor. Take special precautions during
installation and use tools and equipment in perfect working order.
It’s recommended to observe ladders, lifts and other obstacles.
CAUTION
Maintenance inspections should be performed regularly.
Manufacturer recommends the functional and visual checks to be
performed at least once a week. Functional check includes
self-test (see p. VI).
!
!
!
CAUTION
It's strongly recommended to perform the self-test after each
battery replacement to ensure correct device operation.
!
CAUTION
Fibaro Smoke Sensor is equipped with dedicated safety
mechanism (Fig. 2, Fig. 3) which prevents closing the casing
without installed battery.
!
BATTERY REPLACEMENT PROCEDURE:
CAUTION
If fire alarm is triggered, but the level of smoke did not exceed
concentration equal to three times of the sensitivity set in
parameter 1 (the individual levels of sensitivity are printed on the
device casing), user can mute sound alarm by holding the B-button
(temporarily reducing the sensor’s sensitivity). Visual indicator will
still indicate an alarm state by blinking red. If smoke level
concentration is greater than three times of the sensitivity set in
parameter 1, mute will automatically turn off and the device will
alarm fire again (using visual and audible indicator).
!
VI. MALFUNCTION DETECTION
The Fibaro Smoke Sensor can automatically detect a malfunction. As described in
section IV, the device performs a test every 10 seconds. If malfunction is detected
(e.g. damaged smoke chamber) an intermittent sound signal will start and alarm
will be sent to the Z-Wave network controller.
Once trouble alarm has been detected, it’s recommended to dismount the sensor
and:
• check the power source (replace battery),
• check whether the Smoke Sensor is exposed to direct light.
If a trouble alarm is continually reported, it’s recommended to replace Fibaro
Smoke Sensor with new one or contact with guarantor if the product warranty is
still valid.
Self-test may be triggered manually:
1) Make sure the device is powered by the battery
2) Press and hold the B-button. The visual indicator will glow white and the short
alarm will sound. Keep holding the B-button. After 3 seconds from the first beep
smoke chamber operation will be checked.
Triggering fire alarm and beep mean positive result and should occur within 10
seconds. No fire alarm means that the sensor is malfunctioning.
CAUTION
When the self-test is triggered manually the Fibaro Smoke Sensor
sends control command to the Z-Wave network controller. The
procedure will be performed at least as long as the B-button is not
released (will be completed in up to 10 seconds after releasing
B-button).
!
CAUTION
Any service or repair must be carried out by the manufacturer.
The expiry date of the device is indicated on its back.
!
CLOSURE LOCK
LOCKING
MECHANISM
Fig. 3 - Fibaro Smoke Sensor bottom view
with the battery installed
CLOSURE LOCK
VIII. SENSOR’S SENSITIVITY LEVEL CONFIGURATION
Optical smoke detector used in the Fibaro Smoke Sensor has 3 levels of sensitivity,
compliant with EN 14604:2005. By default, the detector is set to the middle sensitivity
level. Sensitivity level depends on the parameter 1 settings (modified only through the
main Z-Wave controller).
IX. RESETTING THE FIBARO SMOKE SENSOR
Resetting the Fibaro Smoke Sensor erases the device memory, including all information
on the Z-Wave network and the main controller.
Fibaro Smoke Sensor reset procedure:
1) Make sure the device has the battery installed.
2) Press and hold the B-button for 3 seconds until visual indicator glows white.
3) Short signal will sound.
4) Release the B-button.
5) Wait until the visual indicator glows yellow, signaling entering the 4th menu option.
6) Press the B-button briefly to confirm your choice.
Successful reset will be confirmed with the visual indicator changing colour to red and
fading. At the same time, short beep will sound, same as at the power connection.
Please use this procedure only in the event that the system primary controller is missing
or otherwise inoperable.
X. OPERATING THROUGH THE Z-WAVE NETWORK
Fibaro Smoke Sensor has a built in smoke detector and a temperature sensor, which
makes it a multi channel device. In the Home Center interface it will be presented as two
devices, depending on the main controller software version:
Fibaro Smoke Sensor ignores incoming BASIC SET command and returns the status of
alarm on BASIC GET command at the moment of wake up. (0 - no alarm, 255 - alarm
active).
CAUTION
Reset procedure should remove Fibaro Smoke Sensor from the Z-Wave
network main controller’s memory (depending on the controller’s
version). Removing the device from the Z-Wave network will reset
Fibaro Smoke Sensor automatically.
Fig. 4 Smoke Sensor icon
in Fibaro Home Center
Fig. 5 Smoke Sensor icon
in Fibaro Home Center
indicating the fire alarm
XI. ASSOCIATIONS
Through an association Fibaro Smoke Sensor may control another Z-Wave network
device, e.g. a Dimmer, Relay Switch, Roller Shutter, RGBW Controller, Wall Plug, or a
scene (scene only through the main controller).
GLOSSARY OF TERMS
• adding - Z-Wave device learning mode, allowing to add the device to existing
Z-Wave network.
• removing - Z-Wave device learning mode, allowing to remove the device from
existing Z-Wave network.
• association (linking devices) - direct control of other devices within the Z-Wave
system network.
• multi-channel association - controlling other multi-channel devices within the
Z-Wave network.
• control command - type of Z-Wave network command enforcing change of
device state.
• report command - type of Z-Wave network command holding an additional
information, e.g. alarm state or measured temperature.
• alarm command - type of Z-Wave network command holding a warning of
danger occurrence, e.g. fire alarm.
• multi-channel device - device having multiple endpoints - various device
functions.
!
Fibaro Smoke Sensor allows for the associations of five groups.
1st group – Lifeline. Reporting device state. Only one device - Z-Wave network
controller may be set in this group. It’s not recommended to modify this association
group.
2nd group – Smoke Alarm. Sending the BASIC SET control command once smoke is
detected. Its value may be modified in advanced parameters (see section XVI). Group
may control up to five on/off devices.
3rd group – Tamper. Sending the notification NOTIFICATION REPORT (TYPE =
BURGLAR, EVENT = PRODUCT COVERING REMOVED) to associated devices once
casing opening is detected. Up to five devices supporting casing opening command
(NOTIFICATION REPORT) may be included in this group.
4th group – Smoke Alarm. Sending the notification SENSOR ALARM REPORT (TYPE
= SMOKE ALARM) to associated devices once smoke is detected. Up to five devices
supporting SMOKE ALARM command may be included in this group
5th group – Tamper. Sending SENSOR ALARM REPORT notification (TYPE =
GENERAL) to associated devices once casing opening is detected. Up to five devices
supporting SENSOR ALARM REPORT command may be included in this group.
Fibaro Smoke Sensor allows for controlling 5 regular or 5 multichannel devices per an
association group in groups 2-5 and one device in the 1st group.
CAUTION
Association allows for direct communication between Z-Wave network
devices. Main controller does not take part in such communication.
Using this mechanism, Fibaro Smoke Sensor may communicate with
other devices even when the main controller is damaged, e.g. in a fire.
!
NOTE
The Fibaro Smoke Sensor is a Security Enabled Z-Wave Plus
product and a Security Enabled Z-Wave Controller must be used
in order to fully utilize the product.
i
Fig. 6 Temperature Sensor
icon in Fibaro Home Center
Praat mee over dit product
Laat hier weten wat jij vindt van de Fibaro FGSD-002 Rookmelder. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.