Handleiding Candy CFT 92 X Afzuigkap

Handleiding voor je Candy CFT 92 X Afzuigkap nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 2 veelgestelde vragen, 0 comments en heeft 0 stemmen. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

ENGLISH
INSTALLATION
The hood is available in the ducting version (air evacuated outside the room) or the filtering version (air recirculated
inside the room).
1) The following operations are essential for assembly:
Install a proper wiring system.
If your apparatus is to be assembled as a Ducting appliance, you must first make the air venting hole and get a
proper pipe to connect the hole to the flange of the hood; use an outlet pipe with: - minimum indispensable length;
- minimum possible bends (maximum angle of bend:90°); - certified material (according to the State); - an as smooth
as possible inside. It is also advisable to avoid any drastic changes in pipe cross-section (recommended diameter:
125 mm). For air evacuation to the outside, follow all the instructions given on the “Warnings” sheet.
Make an air evacuation hole in the wall (diameter 133 mm) as shown in Fig. 1 which gives all the measurements required
for the various possible installations.
2) The hood is fitted with two air outlets, one at the top (Fig. 2B) and one at the rear (Fig. 2A), which can
be used according to requirements. In the ducting version, mount the flange (C) on the opening used and close
the other opening with the plug (E). With the filtering version, the 2 vents DO NOT have to be closed.
3) Wall mounting : Drill 4 holes in the wall using the measurements shown in Fig. 3 and insert the screw anchors;
take 2 of the supplied screws (Fig. 4G) and screw them into the uppermost anchors without tightening them. Attach
the hood to the 2 screws and, working from inside, fully tighten them. Complete mounting by inserting and tightening
the other 2 screws H (Fig. 4).
4) Mounting under a wall unit : If the ducting version of the hood is mounted with the air outlet in the upper opening
(Fig. 2B), before mounting, drill a 133 mm diameter hole in the wall unit (Fig. 5).
Drill 4 holes in the wall unit using the measurements shown in Fig. 6. Attach the hood with 4 screws working from inside
the wall unit.
5) For the ducting version: connect a flex tube to the hood flange using a metal retainer clamp. The tube and clamp
are not included in the supply.
6) Make the electrical connection.
7) CHECK THAT THE DUCTING-FILTERING LEVER IS IN THE RIGHT POSITION: The lever is found on the motor
unit and must be positioned on the symbol (P) in the case of installation in ducting version, on the symbol (Q) in
the case of installation in filtering version (Fig. 7).
8) PAY ATTENTION TO THE CHARCOAL FILTER/S (A) - Fig. 8-9-10-11: One or more charcoal filters are required for
the filtering version. If they are not yet installed in the hood, fit it/them as follows depending on the model you have purchased:
- if the hood is fitted with round charcoal filters (Fig. 11R), fit the charcoal filter by turning it anticlockwise. - if the hood
is fitted with a panel charcoal filter (Fig. 8A or 9A or 10A), position the charcoal filter inside the hood and fit the 2 filter
clips (M) to lock the charcoal filter. The ducting version does not require the charcoal filter/s, therefore, if already fitted
in the hood remove it/them.
OPERATION
The hoods are provided with the following type of controls:
Controls of Fig. 12: A = light switch. B = first speed motor ON/OFF switch. C = second speed switch. D = third
speed switch. E = warning light: indicates motor operation.
Controls of Fig. 13: A = light switch; position 0: light off; position 1: light on. B = motor switch; position 0:
motor off; position 1-2-3: motor first, second and thrid speed motor on. C = warning light: indicates motor operation.
Grease filter/s: Depending on the version, the hood features different types of grease filters:
Modular metal filters (of the type shown in Fig. 14): these are metal filters and must be periodically cleaned, depending
on extent of operation (at least every two months). Wash the filters with neutral detergent.
Panel type metal filter (as shown in Fig. 15N): this is a metal filter and is positioned inside the metal grid; the filter
must be periodically cleaned, depending on extent of operation (at least every two months). Wash the filter with
neutral detergent. Remove the 2 filter retainers (M) and the metal panel filter.
Panel type synthetic filter (as shown in Fig. 16P): this filter is made of white synthetic fibres and is located inside
the metal grid; it cannot be cleaned, but must be replaced from time to time according to use (at least every two
months). Remove the 2 filter retainers (M) and the synthetic panel filter.
Charcoal filter/s: The charcoal filters must be replaced periodically depending on their use, on average every 6 months.
Remove the charcoal filters as follows, depending on the model you have purchased:
- if the hood is fitted with round charcoal filters (Fig. 17R), remove the charcoal filter by turning it clockwise.
- if the hood is fitted with a panel charcoal filter (Fig. 8A or 9A or 10A), remove the 2 filter clips (M) and then remove the
charcoal filter.
Lighting: To replace the incandescent lamps remove the light fitting after unscrewing the setscrew “A” (Fig. 18).
Replace with lamps of the same type.
- To remove the halogen lamps , unscrew the ring nut by turning it anticlockwise (Fig. 19). Replace with lamps of the same
type. WARNING: Do not touch the new lamp with bare hands. Should the halogen lamps not work after replacing them,
cut the power to the hood for a few seconds.
Download de handleiding in het Nederlands en/of Engels (PDF, 1.16 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de Candy CFT 92 X Afzuigkap vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Candy CFT 92 X Afzuigkap?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de Candy CFT 92 X Afzuigkap. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Candy CFT 92 X Afzuigkap. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Candy. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Candy CFT 92 X Afzuigkap in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Candy
Model CFT 92 X
Categorie Afzuigkappen
Bestandstype PDF
Bestandsgrootte 1.16 MB

Alle handleidingen voor Candy Afzuigkappen
Meer handleidingen voor Afzuigkappen

Veelgestelde vragen over Candy CFT 92 X Afzuigkap

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Hoe hoog moet een afzuigkap minimaal boven een kookplaat hangen? Geverifieerd

Dit kan licht verschillen per merk, maar over het algemeen kunt u 65 centimeter aanhouden voor afzuigkappen boven een gaskookplaat en 50 centimeter boven een elektrische of inductiekookplaat. Deze afstanden zijn er ter bevordering van de brandveiligheid.

Ik vind dit nuttig (1213) Lees meer

Heb ik een afzuigkap met of zonder motor nodig? Geverifieerd

Afzuigkappen met motor zijn bedoeld voor wanneer er een directe luchtafvoer naar buiten beschikbaar is. Een afzuigkap zonder motor is bedoeld om aan te sluiten wanneer er een centraal afzuigsysteem is. Sluit nooit een afzuigkap met motor aan op een centraal afzuigsysteem!

Ik vind dit nuttig (635) Lees meer
Handleiding Candy CFT 92 X Afzuigkap

Gerelateerde producten

Gerelateerde categorieën