If the meter still indicates green or “drythe floor is ready for covering. Tests should be made at several points, especially when the
slab is thick and air circulation is poor.
Tests should only be made in newly drilled holes, since the inside surface of the holes can dry out while the rest of the slab is still
wet.
Even readings in the red or “wet” area can indicate relatively low moisture content in concrete. For example, readings in the 85-95
range on the reference scale indicate approximately 2% to 4% moisture content.
If more testing is required, the calcium chloride test is recommended, which measures the moisture vapor emission rate of
concrete. The National Wood Flooring Association
offers the following guidelines when evaluating the results of the calcium chloride test***.
Key Factors to Consider:
The age of the slab. National Wood Flooring Association guidelines specify to wait at least 30 days after the slab is laid
before checking moisture content. ***
Is the slab on grade or suspended? If the slab is on grade, is there an effective vapor barrier under the slab?
How thick is the slab?
What is the drainage condition of the ground?
History of other structures in the area
***Taken from Section V Appendix AA
“Moisture Testing Procedures for Concrete Slab s” NWFA
Testing Brick or Concrete for Paint Application
Brick, stucco, or concrete surfaces must be dry at the time of application and must remain dry after paint is applied or failure of the
paint film may occur. These materials are frequently exposed to unusual moisture conditions that allow them to absorb moisture
through some exposed surface or some structural defect. This is why it is important to check the moisture content of the brick or
concrete when it has been exposed to conditions that permit it to absorb moisture.
Procedure:
Drive two hardened steel masonry nails about 19mm (¾”) apart into the brick or concrete. Drive them about 6.4mm
(¼”) deep so they make firm contact and do not move when touched.
Touch the nails with the contact pins .
Press read button and read the reference scale .
Normally, dry concrete or brick will read in the green or “dry portion of scale, indicating a safe condition to apply paint. Meter
readings should be evaluated in relation to other factors knowledge of the structure, type of paint used, expected weather
conditions in the near future, etc. Paint should not be applied if readings are in the red or “wet portion of the scale.
Do not be misled by surface appearance of masonry materials. Short exposure to rain may thoroughly wet the surface while the
interior is still dry. In this instance, we recommend repeating the test on the masonry below the surface as mentioned above.
Key Areas to Check:
The rear side of brick parapet walls generally are not waterproof above the flashing line and frequently absorb
moisture during rains.
Painted concrete floors on ground subject to peeling as they absorb moisture from the earth, unless an effective
vapor barrier has been installed.
Tests on these materials should be made a day or so after they have been exposed to rain or other high moisture conditions to
verify to what extent they absorb moisture.
Download de handleiding in het Nederlands en/of Engels (PDF, 0.57 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Delmhorst BD-10 Vochtmeter. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Delmhorst. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Delmhorst BD-10 Vochtmeter in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Delmhorst
Model BD-10
Categorie Vochtmeters
Bestandstype PDF
Bestandsgrootte 0.57 MB

Alle handleidingen voor Delmhorst Vochtmeters
Meer handleidingen voor Vochtmeters

Beoordeling

Laat ons weten wat je van de Delmhorst BD-10 Vochtmeter vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Delmhorst BD-10 Vochtmeter?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de Delmhorst BD-10 Vochtmeter. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Handleiding Delmhorst BD-10 Vochtmeter

Gerelateerde producten

Gerelateerde categorieën