Handleiding Drayton Digistat+3 Thermostaat

Handleiding voor je Drayton Digistat+3 Thermostaat nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 2 veelgestelde vragen, 0 comments en heeft 1 stem met een gemiddelde score van 0/100. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

Installation Guide
continuedUser Guide – continued
W
hat is a programmable room
thermostat?
...an explanation for householders
A programmable room thermostat is both a programmer
and a room thermostat. A programmer allows you to set
‘On’ and ‘Off ’ time periods to suit your own lifestyle. A room
thermostat works by sensing the air temperature, switching
on the heating when the air temperature falls below the
thermostat setting, and switching it off once this set
temperature has been reached.
So, a programmable room thermostat lets you choose what
times you want the heating to be on, and what temperature
it should reach while it is on. It will allow you to select
different temperatures in your home at different times of the
day (and days of the week) to meet your particular needs.
Turning a programmable room thermostat to a higher
setting will not make the room heat up any faster. How
quickly the room heats up depends on the design of the
heating system, for example, the size of boiler and radiators.
Neither does the setting affect how quickly the room cools
down. Turning a programmable room thermostat to a lower
setting will result in the room being controlled at a lower
temperature, and saves energy.
The way to set and use your programmable room
thermostat is to find the lowest temperature settings that
you are comfortable with at the different times you have
chosen, and then leave it alone to do its job. The best way to
do this is to set low temperatures first, say 18C, and then
turn them up by one degree each day until you are
comfortable with the temperatures. You won’t have to adjust
the thermostat further. Any adjustments above these settings
will waste energy and cost you more money.
If your heating system is a boiler with radiators, there will
usually be only one programmable room thermostat to
control the whole house. But you can have different
temperatures in individual rooms by installing thermostatic
radiator valves (TRVs) on individual radiators. If you don’t
have TRVs, you should choose a temperature that is
reasonable for the whole house. If you do have TRVs, you can
choose a slightly higher setting to make sure that even the
coldest room is comfortable, then prevent any overheating in
other rooms by adjusting the TRVs.
The time on the programmer must be correct. Some types
have to be adjusted in spring and autumn at the changes
between Greenwich Mean Time and British Summer Time.
You may be able to temporarily adjust the heating
programme, for example, ‘Override’, ‘Advance’ or ‘Boost’.
These are explained in the manufacturer
’s instructions.
Programmable room thermostats need a free flow of air to
sense the temperature, so they must not be covered by
curtains or blocked by furniture. Nearby electric fires,
televisions, wall or table lamps may prevent the thermostat
from working properly.
Hol
Man
Auto
Day
96.5
31.3
137.0
Technical Data
Model 2
2083 22087
Po
wer supply 2 X AA 1.5V 230V AC 50Hz
alkaline batteries
Battery life 3 years typical
Switch rating
Heating (switch N.O.) 16(2)A 230 Vac
Switch type SPDT (voltage free contacts)
Min. recommended current 10mA @24Vac (inductive)
Ambient temperature Operating 0°C to 50°C
Storage – 20°C to 85°C
Ambient humidity
Operating 25% to 85%
(non condensing). Storage 15% to 95%
Temperature range 0°C to 32°C
Accuracy (between 7°C & 3C) 0.5°C
Timing resolution 1 minute
Temperature resolution 0.1°C
Rated impulse voltage 2.5KV
Ball pressure test 75°C
Pollution situation Degree 2
Protection level IP30
Wiring: Designed for fixed wiring only,
to comply with IEE wiring regulations
Dimensions
I
nstaller Options.
I
f you wish to change any of the Installer Options as shown
below, enter the Installer Option Menu from Auto mode by
p
ressing < and + simultaneously for 5 seconds.
P
ressing < and + again for 5 seconds will exit the Menu and
r
eturn to Auto mode.
Once the Installer Options screen has been selected (Fig 8), the
<
and > buttons allow you to scroll through the Menu (shown
b
elow). The + and - allow you to change values. Once a value
h
as been changed pressing > before exiting the Menu will save
the new setting. (Fig 9 shows Option 1 OFF).
Access protection lock.
The access protection lock allows the installer to lock the
Digistat+3 so that the user cannot make any adjustments.
T
he default is OFF mode allowing the users to adjust the
Digistat+3 (see User Guide).
T
o Lock the
D
igistat+3
s
ettings enter the Installer Options Menu
(Refer to Installer Option 1) and select On and press > to accept.
Once the Installer Options Menu is exited all buttons will be
locked.
To switch off the Protection Lock enter the Installer Menu and
change to OFF. Press > to accept.
Once the Installer Menu is exited all buttons will be free to adjust.
Freeze protection.
Freeze protection will switch on the heating if the room
temperature falls to 5ºC and will then control the temperature at
7ºC even if the
Digistat+3 is in OFF mode.
The freeze protection default is ON.
To switch off the Freeze protection mode enter the Installer
Options Menu (Refer to Installer Options 2) and change to OFF.
Press > to accept
.
Low and High Limit set points.
The user temperature set points defaults are High 32ºC and Low
7ºC, to change these limits enter the Installer Options Menu
(Refer to Installer Options 3 & 4).
Intelligent Delayed Start (Energy saving feature).
The Intelligent Delayed Start is an energy saving feature which
automatically reduces the warm up time for the heating system.
As the weather becomes milder, Intelligent Start will delay the
heating start times so that fuel is not wasted bringing the room
up to temperature earlier than necessary.
Note: Intelligent Delayed Start only applies in Auto mode.
Intelligent Delayed Start default is in OFF mode.
To switch on Intelligent Delayed Start enter the Installer Options
Menu (R
efer to Installer Options 5).
Note the Intelligent Delayed start option is not suitable for
Hydronic underfloor application.
Ensure Installer option 5 is set to Off before final commissioning
for Hydronic underfloor application.
Valve protection.
In some hydronic heating systems there may be a requirement to
protect the valve by operating it once a day
, for a given period
without bringing on the heating system.
If valve protection is selected the valve will be operated for a
period as shown in Valve protection time (mins).
Valve protection time every day at 10.00am.
Valve protection default is OFF.
T
o enable the valve protection mode enter the Installer Options
Menu (Refer to Installer Option 6)
V
alve protection time (mins).
Valve protection time can be set between 1 and 5 minutes
(default 3 minutes)
To change this once a day on time enter the Installer Options
Menu (R
efer to Installer Option 7).
(Fig 9)
I
nstaller
O
ptions What is it Select between Default
1 Access protection lock On Off Off
2 Freeze protection On Off On
3
Low limit set point ºC 7 High limit 7
4
High limit set point ºC Low limit 32 32
5 Delayed start
(Energy saving feature) On Off Off
6
Valve protection On Off Off
7
Valve protection time (Mins) 1 5 3
8
Sensor fault function On Off Off
9 Application type 1 0 0
Sensor fault function.
W
hen the display shows an error code (E1) or (E2) this indicates
a
sensor fault and the heating system will
remain Off.
(E1) = internal sensor and (E2) = external sensor.
I
f (E1) is shown the
D
igistat+3
s
hould be replaced.
I
f (E2) is shown, first check the external sensor terminal block
c
onnections before replacing the
D
igistat+3
.
Sensor fault function allows you to temporally set the
Digistat+3
t
o cycle the heating system 30% On and 70% Off until you have
r
eplaced the product.
T
his can be done by entering the installer Option Menu (Option
8) and selecting On. Press > to accept.
T
o reset to default Off, entering the installer Option Menu
(
Option 8) and selecting Off. Press > to accept.
A
pplication type.
Model 22083
(
Battery) can be used for radiator or Hydronic underfloor
a
pplications.
In installer Option select:
0 = Radiator.
1
= Hydronic underfloor.
D
efault 0 = Radiator.
Model 22087
(
Mains) can also be used for electric heat applications.
0
= R
adiator and electric heat.
1
= Hydronic underfloor.
To change application enter the installer Option Menu and refer
t
o (Option 9).
Drayton – Digistat+3 7 day 5:2 day Programmable Room
Thermostat
Allowing different programs for weekdays and weekends and
a
lso every day of the week can be programmed differently.
(Fig 8)
TEAR HERE TEAR HERE
(Fig 11) (Fig 12) (Fig 13)
(Fig 14) (Fig 14a)
(Fig 15)
(Fig 15a)
P
re-set programs for
D
igistat+3
7
day 5-2day.
P
rogram 1 (9 till 5) as shown below
Monday to Friday
E
vents 1 2 3 4 5 6
T
ime 6:30 8:30 12:00 14:00 16:30 22:30
Temperature C 20.0 16.0 16.0 16.0 21.0 7.0
Saturday and Sunday
E
vents 1 2 3 4 5 6
T
ime 7:00 9:00 12:00 14:00 16:00 23:00
Temperature C 20.0 18.0 21.0 18.0 21.0 7.0
P
rogram 2 (Home for lunch)
M
onday to Friday
E
vents 1 2 3 4 5 6
Time 6:30 8:30 12:00 14:00 16:30 22:30
Temperature C 21.0 16.0 21.0 16.0 21.0 10.0
S
aturday and Sunday
E
vents 1 2 3 4 5 6
Time 7:00 9:00 12:00 14:00 16:30 23:00
T
emperature C 21.0 18.0 21.0 18.0 21.0 10.0
P
rogram 3 (Home worker)
Monday to Friday
E
vents 1 2 3 4 5 6
T
ime 6
:00 8:30 12:00 14:00 17:30 22:30
Temperature C 21.0 19.0 21.0 19.0 21.0 16.0
Saturday and Sunday
E
vents 1 2 3 4 5 6
Time 7:00 9:00 12:00 14:00 16:30 23:00
Temperature C 21.0 18.0 21.0 18.0 21.0 16.0
H
ow to change the pre-set time/temperature program to my
o
wn selection.
Press > to select the day function. Now press + to select the day
o
r days you wish to change. The days can be selected as blocks or
a
s individual days (figs 11 to 13).
F
ig 11 showing Monday to Friday as one block.
F
ig 12 showing Saturday and Sunday as one block.
Fig 13 showing Monday through to Sunday as individual days.
Once you have selected the required day or days, press > to
view the existing time/temperature event (1). (Fig 14) time will
flash. Press > again to view the temperature setting, temperature
will flash. Press > again to view the second time temperature
event (Fig 14a).
When you get to the event you wish to change press + or - to
change the required time, then Press > to accept. Use + or - to
select the required temperature, then > to accept.
Digistat+3
will now show the next time/temperature event
. T
o exit press <
until you return to Auto mode.
How to change User Options.
If you wish to change any user options 1 to 8 shown in table 1
they can be accessed from Auto or Man by pressing < and >
simultaneously for 3 seconds. Once you have accessed the user
setting Menu (Fig 15) press > to scroll through selectable
options 1 to 8. The settings for each option can be changed by
pressing + or - as required. Press > to accept the change and
move to the next option. T
o exit press < and > simultaeously for
3 seconds. Alternatively, not pressing any buttons for 2 mins will
cause the
Digistat+3 to return to Auto. (Fig 15a) shows option 1
24 (24 hour clock).
Only selected options which have been accepted by pressing >
will be changed.
How to change from 24hr to 12hr clock (Option 1).
Enter user options, select option 1 and use + and – keys to select
desired option, 12 = 12hr and 24 = 24hr. Press > to accept change.
How to change the default manual set-point temperature
(Option 2).
Enter user options, select option 2 and use + and – keys to set
desired temperature. Press > to accept desired change.
How to change to another predefined program 1, 2 or 3
(Option 3).
Enter user options, select option 3 and use + and – keys to select
desired program 1, 2 or 3. 1 = program 1, 2 = program 2 and
3 = program 3. Press > to accept desired change.
How to change the number of program events per day
(Option 4).
Enter user options, select option 4 and use + and – keys to select
desired option. 2 = 2 time / temp events per day, 4 = 4 time /
temp events per day and 6 = 6 time / temp events per day. Press
> to accept desired change.
How to switch on/off the automatic summer / winter time
change (Option 5).
Twice a year the actual time is automatically changed to keep it in
line with the summer / winter time change. Default setting is On.
If you wish to disable / enable this feature enter user options,
select option 5 and press – or + key to display Off or On as
desired. Press > to accept desired change.
How to change temperature offset (Option 6).
The temperature displayed on the thermostat may not match
that of other temperature measuring devices in the controlled
space, because of its location. The displayed and set
temperature may be offset to bring it in line with other devices.
To adjust the temperature, enter the user options, select option
6. The temperature may be offset by +/- 5 degrees by pressing
the + and – keys. Press > to accept the desired change.
How to restore the built in time temperature programs
(Option 7).
Enter user options, select option 7 and use + and – keys to
select desired option. Off = current programs retained. On =
restore factory program settings. Press > to select the desired
change.
Please note enabling this function will lose any user
changes to the preset programs.
How to switch the Digistat+3 and heating system off
(Option 8).
To switch the Digistat+3 and the heating system off you need to
enable the Off function. Enter user options, select option 8 and
use + or – keys to select On to enable the Off function .The
thermostat and heating system will now be Off unless the
temperature in the controlled space falls below 7
o
C the frost
protection set-point. The LCD will display Off and room
temperature only and the keys will not function. To switch On
the
Digistat+3 enter user options select option 8 and use + or –
keys to select Off to disable the Off function. The thermostat
will now regulate the heating system in line with the currently
selected program. Please note this does not effect the operation
of domestic hot water where provided.
User
options What is it Min Max Default
1 Change 12h or 24h clock 12 24 24
2 Change the manual set
point temperature
0
C7
0
C 32
0
C 20
0
C
3 Change to another
pre-set programme 1 3 1
4
Change the number of
programme events per day
2, 4 or 6 6
5 Switch on/off automatic
summer/winter time change On Off On
6 Change temperature offset
0
C-5 5 0
7 Restore pre-set programme On Off Off
8 To enable Off function On Off Off
(T
able 1)
06490044001 Digistat+3 update 7/3/06 11:19 am Page 2
Download de handleiding in het Nederlands en/of Engels (PDF, 2.9 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de Drayton Digistat+3 Thermostaat vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Drayton Digistat+3 Thermostaat?
Ja Nee
0%
100%
1 stem

Praat mee over dit product

Laat hier weten wat jij vindt van de Drayton Digistat+3 Thermostaat. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Drayton Digistat+3 Thermostaat. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Drayton. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Drayton Digistat+3 Thermostaat in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Drayton
Model Digistat+3
Categorie Thermostaten
Bestandstype PDF
Bestandsgrootte 2.9 MB

Alle handleidingen voor Drayton Thermostaten
Meer handleidingen voor Thermostaten

Veelgestelde vragen over Drayton Digistat+3 Thermostaat

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Wat is de dode zone van een thermostaat? Geverifieerd

Veel modernere thermostaten hebben een dode zone. Als de temperatuur minder dan ongeveer 4°C afwijkt van de ingestelde temperatuur, dan zal het systeem niet verwarmen of koelen. Deze zogenoemnde dode zone van de thermostaat voorkomt dat het systeem te vaak aan- en afslaat en bespaart zo energie.

Ik vind dit nuttig (1592) Lees meer

Wat is de beste locatie om een thermostaat te plaatsen? Geverifieerd

De beste plek voor een thermostaat is ongeveer 1,5 meter van de grond. Plaats de thermostaat niet in de buurt van een radiator of andere apparatuur die warmte afgeeft of in direct zonlicht. Kies een kamer die vaak wordt gebruikt. In veel gevallen is dit de woonkamer.

Ik vind dit nuttig (996) Lees meer
Handleiding Drayton Digistat+3 Thermostaat

Gerelateerde producten

Gerelateerde categorieën