Handleiding voor je FERM CRM1005 FC-710 Compressor nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 0 veelgestelde vragen, 0 comments en heeft 0 stemmen. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

Ferm 192 Ferm
Product: Ferm Compressor
Type FC-710, Art. nr. 231710
Ferm, Genemuiden, The Netherlands
1. TECHNICAL DATA
This is a directly linked 1-cylinder compressor in mobile
design. This compressor is also equipped with a reducing
valve, a automatic shutdown and a quick coupling.
Sound pressure level 83,8 dB(A)
CAREFULLY READ THE INSTRUCTIONS
BEFORE YOU USE THE COMPRESSOR!
2. SPECIFIC SAFETY RULES
BEFORE USING THE COMPRESSOR:
1. Place the compressor in a well ventilated, frost
free area.
To obtain sufficient ventilation and cooling the distan-
ce between the shield and the wall needs to be at least
50 to 60 cm.
2. The following points need to be checked:
- do the voltage of the engine and the engine safe
guard, if any, correspond to the mains voltage (ap-
pliances for a mains voltage of 230 V can be connec-
ted to a mains voltage of 220 V without any pro-
blems);
- an earthed mains connection (wall socket) needs
to be used;
- are the mains lead and the mains plug in a good con-
dition: solid, without any loose ends or damage;
- the pressure reducing valve may not be copletely
closed so as to prevent damage to membranes;
- the oil level with help from the gauge. The oil level
should be within the area indicated by both marks
on the gauge, when the compressor is placed level.
-before use the air tank needs to be empty.
IMPORTANT: To prevent damage to the motor
windings as a result of voltage variation it is advisable
to mount an engine safety switch.
WHILE USING THE COMPRESSOR:
1. Do not use extension cables which are too long.
IMMEDIATELY SWITCH OFF THE COMPRES-
SOR IN CASE OF:
1. defective mains plug, mains line or damage to the
mains line;
2. defective switch;
3. smoke or bad smell caused by scorched insulation.
3. INSTALLATION
The compressor needs to be placed in well-ventilated,
frost-free area. To obtain sufficient ventilation and coo-
ling the distance between the shield and the wall needs to
be at least 50 to 60 cm.
4. OPERATING THE COMPRESSOR
- The mains switch needs to be in “OFF” or “0” posi-
tion before the mains plug is connected to the mains
voltage.
- Bij switching the switch to “ON” or “1” the compres-
sor will operate.
- Always keep the mains lead away from moving parts
of any linked up air-pressure equipment.
-With the use of the reducing valve it is possible to ad-
just the air pressure by hand. By pressing the reducing
valve the chosen position can be locked. However, do
not close the reducing valve too much, in order to
prevent damage to the membranes.
5. MAINTENANCE
The mains plug always needs to be taken out
of the socket (the mains socket) during main-
tenance or cleaning activities. Never use wa-
ter or other agressive liquids to clean the ma-
chine. Clean the machine by brushing it with
a brush.
PERIODIC MAINTENANCE OF THE COMPRES-
SOR WILL PREVENT UNNECESSARY PROBLEMS!
Oillevel
The compressor comes with a special test oil, that must
be Replaced after about 100 hours of use. Check the oil
level from time to time, using the oil gauge.
When the compressor is level and has not been used for
some time, the oil level should be within the area indica-
ted by both marks on the gauge. The oil must be replaced
after every 1000 hours of use. Use compressor oil API
CC SAE 40 rather than motor oil. If the compressor is
!
GB
English
Art.
nr.
Type
V~/Hz W RPM LTR. L/MIN BAR
231710 FC-710 230~50 1.500 2.800 50 245 8
1'
Exploded
view 2
FC-710
AVAILABLE SPARE PARTS FOR FC-710
REF.NR. DESCRIPTION FERM NR.
1 CYLINDER COVER (RED) 208217
2REAR COVER 208200
3 COVER 208201
6 VALVE PLATE 208252
7 FAN 208202
9 OIL LEVEL GAUGE 208203
11 CRANKSHAFT + AXLE 208204
8223091 CONNECTION ROD COMPLETE 208205
21 CONDENSOR 25 uF 800025
23 CYLINDER 208210
24 CYLINDER HEAD PACKING 208211
26 GASKET VALVE PLATE HEAD 208212
27 HEAD 208213
29 FILTER 205730
30 STATOR 208221
31 ROTOR 208222
32 CYLINDER PACKING 208216
Download de handleiding in het Nederlands en/of Engels (PDF, 0.5 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de FERM CRM1005 FC-710 Compressor vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de FERM CRM1005 FC-710 Compressor?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de FERM CRM1005 FC-710 Compressor. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je FERM CRM1005 FC-710 Compressor. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met FERM. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van FERM CRM1005 FC-710 Compressor in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk FERM
Model CRM1005 FC-710
Categorie Compressors
Bestandstype PDF
Bestandsgrootte 0.5 MB

Alle handleidingen voor FERM Compressors
Meer handleidingen voor Compressors

Handleiding FERM CRM1005 FC-710 Compressor

Gerelateerde producten

Gerelateerde categorieën