Handleiding Haier HSU19EH-TXS3BE-INV Airconditioner

Handleiding voor je Haier HSU19EH-TXS3BE-INV Airconditioner nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 7 veelgestelde vragen, 0 comments en heeft 0 stemmen. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

Operation
Emergency operation and test operation
Sleep Operation
Turbo/Quiet Operation
Press the
cancel
TURBO
QUIET
When you need fast cool or fast
dehumidification,you can choose
the Turob function; when you sleep,
read, you can choose Quiet function
bu on, you can switch the “Turbo” and
swith as
When running in Turbo the fan speed is the highest,
when running in Quiet, the fan speed is super slow
below
“Quiet”
will
Air Flow Direction Adjustment
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test ope ration switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 23
o
C 26
o
C AUTO COOL
No
Press “DRY” Button, when the LCD displays ,
Dry Mode is set.
In Dry mode, compressor will stop to operate when the room
temperature is below the setting temperature. If the room
temperature is higher than the setting temperature, the logic
circuit will control the operation of compressor and indoor
fan speed, in order to cause dew formation on cooling coil to
obtain the effect of dehumification. In dry mode ,it is normal
Dry Operation
Timer Operation
Health airflow Operation
1. Set ON timer
.
Press set the duration (hour).
Press “CONFIRM/CANCEL”.
2. Set OFF timer
Press to close the screen
Healthy
airflow
upwarder
Healthy
airflow
downwarder
fixed
location
1.Press to starting
Setting the comfort work conditions.
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
3.In cooling and dry , using the air conditioner for a long
time under the high air humidity, condensate water
may occur at the grille .
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly,
stop for a minute and then start, adjusting by remote
controller.
2.In cooling, it is better to select the
mode.
Operation
that the indoor fan speed is lower than other operation mode.
SELF
CLEAN
TIMER
Self Clean Operation
Functional description: the purpose of this function is to
clean the evaporator.
Entry and exit Press self clean button to enter this
function, then it will display "CL" on the panel of the indoor
unit and also on the remote controller. After running 18-21
minutes, this function will exit automatically with the " Pi "
sound is heard twice, then the unit return to original state.
Under operation process of self clean, press the button
repeatedly has no effect and cannot exit, but the power off
button and other mode button can make it exit.
Note:
1.It has no effect under the mode of timer/sleep.
2.After this mode starts, the air volume may reduce or
even have no airflow.
3.It is normal if the unit make some sound like expand with
heat and contract with cold
4. The “CL” display time may last differently on the remote
controller and panel.
5.It is normal if the temperature is below 0 outside, the
unit may display "F25"under this mode running.
Please turn off the unit for 10 seconds then restart.
6.The best condition to run this mode: the temperature is
15~27 and the humidity is 35~60 in the door,
the temperature is 30~40℃(cooling season
7.It is hard to frost if the air is too dry(humidity20%). and
if the humidity is too high(humidity70%),
the condensate water may increase, which may move away
some frost.
2.The setting of healthy airflow function
Press button to enter additional options,Press this
button continuously, the louvers location will cycle between
in the following three locations, to choose the swing location
what you needed,and then press button to confirm.
Operation Mode
1. In COOL,DRY mode
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 1
O
C
Rises 1
O
C
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
Note:
When TIMER function is set, the sleeping function can’t be
set up .After the sleeping function is set u
p
,
TIMER function, the sleeping function will be cancelled; the
machine will be in the state of
timing-on.
1 hours after SLEEP mode starts,temp.will become
higher than temp.setting.After another 1 hours,temp.rises
by 1 futher.The unit will run for further
6 hours then stops
T
emp. is higher than temp.setting so that room temperature
won’t be too low for your sleep.
O
C
1
O
C
if user resets
Before going to bed,you can simply press the SLEEP
button and unit will operate in SLEEP mode and bring
you a sound sleep.
SLEEP
Move the vertical blade by a knob on airconditioner
to adjust left and right direction referring to Fig.
4.Left and right air flow adjustment(manual)
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
adjusted to left or at air outlet if all vertical louvers are right.
mode ,
Pos.1
Pos.2
3.Press
button
to choose the and
1.Status display of air flow
For each press of button, remote controller
displays as follows :
remote controller:
Vertical flap
COOL/DRY:
HEAT:
No initial state disaplayed on remote controller,
the vertical flap will be fixed on the current position
SLEEP
operation starts
SLEEP
operation stops
1 hr
1 hr
3 hrs
3 hrs
Rises 1
O
C
Temp.setting
Unit stop
In HEAT mode
Decreases 2
O
C
Decreases 2
O
C
2.
In HEAT mode
1 hours after SLEEP mode starts,temp will become 2
lower than temp.setting.After another 1 hours,temp
decrease by 2
rises
by 1 futher.The unit will run for further 3 hours then
stops.Temp.is lower than temp. setting so that room
temperature won’t be too high for your sleep.
O
C futher.After more another 3 hours,temp.
O
C
O
C
3.
In AUTO mode
The unit operaters in corresponding sleep mode
adapted to the automatically selected operation
mode.
If the wind speed is high or middle before setting for the
sleep, set for lowing the wind speed after sleeping.
If it is low wind, no change.
5.Set the wind speed change when sleeping
4. In FAN mode
It has no SLEEP function.
PiPi
PiPi
Quiet
Turbo
Quiet
Turbo
TIMER
Press to activate the screen
Press set the duration (hour).
Press “CONFIRM/CANCEL”.
TIMER
Energy Control Operation
25
45
step
1.
2.
Note:
1 step : The strong air blows out to cool indoor air quickl
y
.
2 step : The power input is 100% of rated power.
3
4
5
3 4 5
+
+
Download de handleiding in het Nederlands en/of Engels (PDF, 4.62 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de Haier HSU19EH-TXS3BE-INV Airconditioner vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Haier HSU19EH-TXS3BE-INV Airconditioner?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de Haier HSU19EH-TXS3BE-INV Airconditioner. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Haier HSU19EH-TXS3BE-INV Airconditioner. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Haier. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Haier HSU19EH-TXS3BE-INV Airconditioner in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Haier
Model HSU19EH-TXS3BE-INV
Categorie Airconditioners
Bestandstype PDF
Bestandsgrootte 4.62 MB

Alle handleidingen voor Haier Airconditioners
Meer handleidingen voor Airconditioners

Veelgestelde vragen over Haier HSU19EH-TXS3BE-INV Airconditioner

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Hoe vaak moet ik de filters van mijn airconditioner vervangen of schoonmaken? Geverifieerd

Het is aan te raden de filters van de airconditioner 4 keer per jaar te controleren. Vervuilde filters kunnen met een stofzuiger uitgezogen worden of, afhankelijk van het type, gewassen worden. Tijdens jaarlijks onderhoud dient een professional te bepalen of de filters aan vervanging toe zijn.

Ik vind dit nuttig (2683) Lees meer

Waar staat BTU voor? Geverifieerd

BTU staat voor British Thermal Unit. Dit is een eenheid voor koelend vermogen.

Ik vind dit nuttig (950) Lees meer

Werkt elke airconditioner ook als luchtontvochtiger? Geverifieerd

De koude lucht die uit een airconditioner komt heeft vaak een vrij lage luchtvochtigheid. Toch is het effect minder dan bij het gebruik van een daadwerkelijke luchtontvochtiger. Sommige airconditioners hebben wel een speciale functie om de lucht te ontvochtigen.

Ik vind dit nuttig (708) Lees meer

Wat is R-410A? Geverifieerd

R-410A is een koelmiddel dat wordt gebruikt in apparaten die koelen tot 0°C, zoals koelkasten en airconditioners. Het is de vervanger van oudere koelmiddelen en brengt geen schade toe aan de ozonlaag.

Ik vind dit nuttig (486) Lees meer

Wat is de beste plaats om de binnenunit van een split-type airconditioner te plaatsen? Geverifieerd

Dit hangt af van de ruimte, maar over het algemeen kunnen de volgende regels aangehouden worden. Zorg dat de verspreiding van lucht niet belemmerd wordt. Zorg dat de plek toegankelijk is voor onderhoud. Zorg dat de unit op minimaal 2 meter hoogte geplaatst wordt.

Ik vind dit nuttig (350) Lees meer

Kan ik mijn mobiele airconditioner in een kastje plaatsen om hem uit zicht te houden? Geverifieerd

Nee, absoluut niet. Een mobiele airconditioner heeft ruimte nodig voor de aanvoer en afvoer van verse lucht. In een te kleine ruimte kan het apparaat oververhitten.

Ik vind dit nuttig (348) Lees meer

Heeft een airconditioner een negatieve invloed op de luchtkwaliteit? Geverifieerd

Als de airconditioner goed is onderhouden dan heeft deze geen invloed op de luchtkwaliteit. Als echter bijvoorbeeld een filter lang niet is vervangen of andere vormen van onderhoud niet worden uitgevoerd, dan kan een airconditioner vieze lucht produceren.

Ik vind dit nuttig (346) Lees meer
Handleiding Haier HSU19EH-TXS3BE-INV Airconditioner

Gerelateerde producten

Gerelateerde categorieën