The Halstead Eden CBX 24, 32 & 38, SBX 30 and Eden CBX 24, 32 & 38
SBX 30 Propane are high efficiency condensing, fully automatic, wall
mounted gas appliances for use with natural gas or propane. The
appliances incorporate a microprocessor based, fully modulating pre-mix
gas control system with direct burner ignition.
The Eden CBX 24 provides central heating at outputs between 5.9 kW
(20,100 BTU/h) and 19.3 kW (65,900 BTU/h) and instantaneous domestic
hot water at outputs between 5.9 kW (20,100 Btu/h) and 24.0 kW (81,900
Btu/h).
The Eden CBX 32 provides central heating at outputs between 7.9 kW
(27,000 BTU/h) and 25.7 kW (87,700 BTU/h) and instantaneous domestic
hot water at outputs between 7.9 kW (27,000 Btu/h) and 32.0 kW (109,200
Btu/h).
The Eden CBX 38 provides central heating at outputs between 9.0 kW
(30,700 BTU/h) and 32.1kW (109,500 BTU/h), and instantaneous domestic
hot water at outputs between 9.0kW (30,700 BTU/h) and 38.0kW (129,600
BTU/h).
The Eden SBX 30 provides central heating at outputs between 8.2 kW
(28,000 BTU/h) and 30.0 kW (102,400 BTU/h).
The Eden CBX & SBX Propane versions are similar in performance but
use propane instead of natural gas. Heat output is controlled according to
demand (in both domestic hot water and central heating modes) by the
fully modulating pre-mix burner control. The appliance always gives
priority to domestic hot water supply.
The appliance incorporates frost protection. However this is not
operational when the main switch on the appliance is in the off position,
or the electrical supply to the appliance is isolated. An electro/mechanical
24hr time clock is fitted as standard (Eden CBX 24/32 & 38 only).
Gas Consumer Council
The Gas Consumer Council (GCC) is an independent organization which
protects the interests of gas users. If you need advice, you will find the
telephone number in your local directory under 'Gas'.
Where an open flued (B23) system is used (for example KIT E ' Flexible flue
liner kit for chimney') then an air vent must be provided in the same room
or internal space as the flue duct air inlet with a minimum free-area as
stated in the boilers instructions.
Please ensure that you have a Logbook supplied with your appliance. This
Logbook should be completed by your installer to verify that the correct
installation and commissioning procedure was followed.
Failure to complete the Logbook may result in difficulties should a problem
arise with your appliance during the guarantee period.
This Logbook forms part of the industry's Benchmark code of practice for
the installation, commissioning and servicing of central heating systems.
All CORGI Registered Installers carry a CORGI ID card and have a
registration number. Both should be recorded in your Logbook. You can
check your installer is CORGI registered by calling CORGI on 01256 37230.
On a demand for DHW (Eden CBX 24/32), water flow is detected and the
ignition sequence initiated. The fan and pump will start and the boiler will
light.
If the DHW draw off rate is high (approx 13l/min.), the appliance will run
continuously at full output until the tap is either turned off, or the flow rate
is reduced, in which case the heat supplied will reduce accordingly to
maintain a steady temperature (60°C max)
Hot water is made available at the appliance outlet almost immediately,
but the final temperature and time taken for the hot water to reach a tap
depends upon the thermostat setting, the rate at which water is drawn off
and the length of the pipe runs between the boiler and taps.
When the tap is turned off, the appliance after a short period of time will
revert to heating mode if there is a demand. Otherwise the burner will be
extinguished until the next demand for hot water. The burner may stay on
for few seconds (see the Installation and Servicing Instructions clause 5.8
'Keep hot facility').
Priority is always given to DHW demand.
With no call for heat, the boiler will fire periodically for a few seconds to
maintain the DHW plate heat exchanger in a preheated condition.
This feature can automatically adjust to the user's habitual requirements.
Thus, during long stand still periods, such as overnight, no pre-heat is
provided.
The preheat feature can also be switched off by turning the DHW
temperature control knob to the Economy position and then turning the
DHW temperature control back to the desired temperature setting.
Repeating this procedure will turn the pre-heat back on.
Refer to Fig. 1
Read these user manual instructions or the user label (fitted inside the
lower decorative front panel) carefully before attempting to operate the
appliance. Comply with all applicable warnings. Do not interfere with any
sealed components and use the appliance only in accordance with these
instructions.
It is the law that all gas appliances are installed by a competent person in
accordance with the above regulations. Failure to install appliances
correctly could lead to prosecution. It is in your own interest, and that of
safety, to ensure that the law is complied with. If the appliance is damaged,
turn off the appliance and consult a CORGI registered installer.
If it is known or suspected that a fault exists on the appliance it MUST NOT
be used until the fault has been rectified by a competent person.
This appliance must be earthed.
Supply: 230V - 50Hz fused at 3A. The method of connection to the mains
supply must facilitate complete isolation of the appliance. Either a 3A fused
three pin plug and unswitched shuttered socket outlet, or a 3A fused
double pole switch having a 3 mm contact separation in both poles, serving
only the boiler (and its external controls), may be used.
It is not necessary to have a purpose provided air vent in the room or
internal space in which a room-sealed appliance is installed.
Cupboard or compartment ventilation is not necessary for a room-sealed
appliance providing that the minimum clearances are maintained.
INTRODUCTION
1
SAFETY
2
ELECTRICAL SUPPLY
2.2
CLEARANCES AND VENTILATION
2.3
CURRENT GAS SAFETY (INSTALLATION AND
USE) REGULATIONS OR THE RULES IN FORCE
3
BOILER LOGBOOK
3
APPLIANCE OPERATION
4
OPERATING INSTRUCTIONS
5
TO LIGHT THE BOILER
5.1
1) Check that the electricity supply to the boiler is OFF.
2) Check that the two CH and one DHW (Eden CBX) isolation valves
underneath the appliance are OPEN.
3) Set the boiler ON/OFF switch to OFF.
4) Set the CH temperature control knob to the '+' position (approx. 80°C).
5) Set the DHW temperature control knob to the '+' position (approx.
60°C). On the Sbx the DHW control knob is disabled if the appliance is
connected to a 'Y' or 'S' plan system.
6) Turn all DHW taps off.
7) Ensure that the standard fitted clock (Eden CBX) is set to an ON
period, or set the override switch to the ON position.
8) Check that all external controls, eg. programmer, room thermostat,
are ON and switch ON the electricity supply to the boiler.
Download de handleiding in het Nederlands en/of Engels (PDF, 0.35 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de Halstead Eden CBX 24 CV-ketel vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Halstead Eden CBX 24 CV-ketel?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de Halstead Eden CBX 24 CV-ketel. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Halstead Eden CBX 24 CV-ketel. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Halstead. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Halstead Eden CBX 24 CV-ketel in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Halstead
Model Eden CBX 24
Categorie CV-ketels
Bestandstype PDF
Bestandsgrootte 0.35 MB

Alle handleidingen voor Halstead CV-ketels
Meer handleidingen voor CV-ketels

Veelgestelde vragen over Halstead Eden CBX 24 CV-ketel

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Wat is de juiste druk voor de CV-ketel? Geverifieerd

De juiste druk ligt tussen de 1 en 1,5 bar. Laat de druk nooit oplopen boven de 2 bar.

Ik vind dit nuttig (508) Lees meer

De leidingen en radiatoren maken lawaai. Wat is daarvan de oorzaak? Geverifieerd

Er zit zeer waarschijnlijk lucht in het verwarmingssysteem. Het is raadzaam om het systeem te ontluchten.

Ik vind dit nuttig (275) Lees meer