Handleiding voor je Mitsubishi MSZ-FD09NA Airconditioner nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 7 veelgestelde vragen, 0 comments en heeft 1 stem met een gemiddelde score van 100/100. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

En-10
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated. Is the breaker turned on?
Is the power supply plug connected?
Is the ON timer set? Page 8
The horizontal vane does not
move.
Are the horizontal vane and the vertical vane
installed correctly? Page 9
The unit cannot be operated
for about 3 minutes when
restarted.
This protects the unit according to instruc-
tions from the microprocessor. Please
wait.
Mist is discharged from the air
outlet of the indoor unit.
The cool air from the unit rapidly cools mois-
ture in the air inside the room, and it turns
into mist.
The swing operation of the
HORIZONTAL VANE is
suspended for a while, then
restarted.
This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
The air fl ow direction changes
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.
When the unit is operated in COOL or DRY
mode, if the operation continues with air
blowing down for 0.5 to 1 hour, the direction
of the air fl ow is automatically set to position
(1) to prevent water from condensing and
dripping.
In the heating operation, if the air flow
temperature is too low or when defrosting is
being done, the horizontal vane is automati-
cally set to horizontal position.
The operation is stopped for
about 10 minutes in the heat-
ing operation.
Defrosting of the outdoor unit is being
done.
Since this is completed in max.10 minutes,
please wait. (When the outside temperature
is too low and humidity is too high, frost is
formed.)
The unit starts operation by
itself when the main power
is turned on, though it isn’t
operated with the remote
controller.
These models are equipped with an auto re-
start function. When the main power is turned
off without stopping the unit with the remote
controller and is turned on again, the unit
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shutoff of the main power.
Refer to “Auto restart function”. Page 6
Multi system
The indoor unit which is not
operating becomes warm and
a sound, similar to water fl ow-
ing, is heard from the unit.
A small amount of refrigerant continues to
ow into the indoor unit even though it is
not operating.
When heating operation is
selected, operation does not
start right away.
When operation is started during defrosting
of outdoor unit is done, it takes a few minutes
(max. 10 minutes) to blow out warm air.
Outdoor Unit
The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.
When the outside temperature is low dur-
ing cooling operation, the fan operates
intermittently to maintain suffi cient cooling
capacity.
Water leaks from the outdoor
unit.
During COOL and DRY operations, pipe or
pipe connecting sections are cooled and this
causes water to condense.
In the heating operation, water condensed
on the heat exchanger drips down.
In the heating operation, the defrosting op-
eration makes water frozen on the outdoor
unit melt and drip down.
Symptom Explanation & Check points
Outdoor Unit
White smoke is discharged
from the outdoor unit.
In the heating operation, vapor generated
by the defrosting operation looks like white
smoke.
Remote controller
The display on the remote
controller does not appear
or it is dim. The indoor unit
does not respond to the
remote control signal.
Are the batteries exhausted? Page 4
Is the polarity (+, -) of the batteries correct?
Page 4
Are any buttons on the remote controller of
other electric appliances being pressed?
Does not cool or heat
The room cannot be cooled
or heated suffi ciently.
Is the temperature setting appropriate?
Page 6
Is the fan setting appropriate? Please
change fan speed to higher setting.
Page 7
Are the fi lters clean? Page 9
Is the fan or heat exchanger of the indoor unit
clean?
Are there any obstacles blocking the air inlet
or outlet of the indoor or outdoor unit?
Is a window or door open?
The room cannot be cooled
suffi ciently.
When a ventilation fan or a gas cooker is
used in a room, the cooling load increases,
resulting in an insuffi cient cooling effect.
When the outside temperature is high, the
cooling effect may not be suffi cient.
The room cannot be heated
suffi ciently.
When the outside temperature is low, the
heating effect may not be suffi cient.
Air does not blow out soon in
the heating operation.
Please wait as the unit is preparing to blow
out warm air.
Airfl ow
The air from the indoor unit
smells strange.
Are the fi lters clean? Page 9
Is the fan or heat exchanger of the indoor unit
clean?
The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it
out with the air.
Sound
Cracking sound is heard. This sound is generated by the expansion/
contraction of the front panel, etc. due to
change in temperature.
“Burbling” sound is heard. This sound is heard when the outside air is
absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
Mechanical sound is heard
from the indoor unit.
This is the switching sound in turning on/off
the fan or the compressor.
The sound of water fl owing
is heard.
This is the sound of refrigerant or condensed
water fl owing in the unit.
Hissing sound is sometimes
heard.
This is the sound when the ow of refrigerant
inside the unit is switched.
In the following cases, stop using the air conditioner and consult your dealer.
When water leaks or drips from the indoor unit.
When the POWER lamp blinks.
When the breaker trips frequently.
The remote control signal is not received in a room where an electronic ON/OFF
type uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
Operation of the air conditioner interferes with radio or TV reception. An ampli-
er may be required for the affected device.
When an abnormal sound is heard.
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
SG79F214H03_En.indd 10 2008/11/12 14:24:11
Download de handleiding in het Nederlands en/of Engels (PDF, 5.24 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Beoordeling

Laat ons weten wat je van de Mitsubishi MSZ-FD09NA Airconditioner vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Mitsubishi MSZ-FD09NA Airconditioner?
Ja Nee
100%
0%
1 stem

Praat mee over dit product

Laat hier weten wat jij vindt van de Mitsubishi MSZ-FD09NA Airconditioner. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Mitsubishi MSZ-FD09NA Airconditioner. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Mitsubishi. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Mitsubishi MSZ-FD09NA Airconditioner in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Mitsubishi
Model MSZ-FD09NA
Categorie Airconditioners
Bestandstype PDF
Bestandsgrootte 5.24 MB

Alle handleidingen voor Mitsubishi Airconditioners
Meer handleidingen voor Airconditioners

Veelgestelde vragen over Mitsubishi MSZ-FD09NA Airconditioner

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Hoe vaak moet ik de filters van mijn airconditioner vervangen of schoonmaken? Geverifieerd

Het is aan te raden de filters van de airconditioner 4 keer per jaar te controleren. Vervuilde filters kunnen met een stofzuiger uitgezogen worden of, afhankelijk van het type, gewassen worden. Tijdens jaarlijks onderhoud dient een professional te bepalen of de filters aan vervanging toe zijn.

Ik vind dit nuttig (2746) Lees meer

Waar staat BTU voor? Geverifieerd

BTU staat voor British Thermal Unit. Dit is een eenheid voor koelend vermogen.

Ik vind dit nuttig (987) Lees meer

Werkt elke airconditioner ook als luchtontvochtiger? Geverifieerd

De koude lucht die uit een airconditioner komt heeft vaak een vrij lage luchtvochtigheid. Toch is het effect minder dan bij het gebruik van een daadwerkelijke luchtontvochtiger. Sommige airconditioners hebben wel een speciale functie om de lucht te ontvochtigen.

Ik vind dit nuttig (753) Lees meer

Wat is R-410A? Geverifieerd

R-410A is een koelmiddel dat wordt gebruikt in apparaten die koelen tot 0°C, zoals koelkasten en airconditioners. Het is de vervanger van oudere koelmiddelen en brengt geen schade toe aan de ozonlaag.

Ik vind dit nuttig (518) Lees meer

Heeft een airconditioner een negatieve invloed op de luchtkwaliteit? Geverifieerd

Als de airconditioner goed is onderhouden dan heeft deze geen invloed op de luchtkwaliteit. Als echter bijvoorbeeld een filter lang niet is vervangen of andere vormen van onderhoud niet worden uitgevoerd, dan kan een airconditioner vieze lucht produceren.

Ik vind dit nuttig (372) Lees meer

Kan ik mijn mobiele airconditioner in een kastje plaatsen om hem uit zicht te houden? Geverifieerd

Nee, absoluut niet. Een mobiele airconditioner heeft ruimte nodig voor de aanvoer en afvoer van verse lucht. In een te kleine ruimte kan het apparaat oververhitten.

Ik vind dit nuttig (370) Lees meer

Wat is de beste plaats om de binnenunit van een split-type airconditioner te plaatsen? Geverifieerd

Dit hangt af van de ruimte, maar over het algemeen kunnen de volgende regels aangehouden worden. Zorg dat de verspreiding van lucht niet belemmerd wordt. Zorg dat de plek toegankelijk is voor onderhoud. Zorg dat de unit op minimaal 2 meter hoogte geplaatst wordt.

Ik vind dit nuttig (370) Lees meer
Handleiding Mitsubishi MSZ-FD09NA Airconditioner

Gerelateerde producten

Gerelateerde categorieën