CONTENTS
C.6 Service Manual MEK-6400/6410/6420
Disinfecting the Surface of the Analyzer ................................................... 6.16
Cleaning the Surface of the Analyzer ........................................................ 6.16
Checking the Reagents Connection Tubes .......................................................... 6.16
Checking the Power Cord and Grounding Lead.................................................... 6.16
Checking the External Instrument Connection ....................................................6.16
Checking the Power On ....................................................................................... 6.17
Calibrating the Touch Screen ..................................................................... 6.17
Checking the Date and Time ............................................................................... 6.17
Clock Accuracy......................................................................................... 6.18
Measuring Background Noise.............................................................................. 6.18
Measuring Hematology Control ........................................................................... 6.20
Checking Measurement Baths and Sub Baths .................................................... 6.21
Checking Pump Tube ........................................................................................... 6.21
Weekly/Every 300 Counts Maintenance Procedures ..................................................... 6.21
Checking/Cleaning Filters ................................................................................... 6.21
Monthly/Every 1,000 Counts Maintenance Procedures ................................................. 6.22
Replacing Filters ................................................................................................. 6.22
Materials Required .................................................................................... 6.22
Procedure ................................................................................................. 6.22
Checking and Cleaning Measurement Baths and Sub Baths ............................... 6.23
Materials Required .................................................................................... 6.23
Procedure ................................................................................................. 6.24
Checking and Cleaning/Replacing the Rinse Unit and Cap Pierce Nozzle ........... 6.26
Materials Required .................................................................................... 6.26
Procedure ................................................................................................. 6.27
Every Four Months/Every 3,000 Counts Maintenance Procedures ............................... 6.29
Checking and Cleaning/Replacing the Sampling Nozzles .................................... 6.29
Materials Required .................................................................................... 6.29
Procedure ................................................................................................. 6.29
Replacing Pump Tube .......................................................................................... 6.32
Materials Required .................................................................................... 6.32
Procedure ................................................................................................. 6.32
Every Six Months/As-Required Maintenance Procedures ............................................. 6.35
Removing a Clog from the Aperture .................................................................... 6.35
Cleaning Aperture Caps ...................................................................................... 6.36
Materials Required .................................................................................... 6.36
Procedures................................................................................................ 6.36
Cleaning the External Electrodes on the Measurement Baths ............................ 6.39
Checking the Sensor Monitor Screen .................................................................. 6.40
Checking the Circuit ............................................................................................ 6.41
Checking the X
_
-R Values .....................................................................................6.43
Checking the Current Calibration Coefficients ..................................................... 6.43
Checking the New Calibration Coefficients .......................................................... 6.43
Checking the Prime Function .............................................................................. 6.44
Checking the Drain Function ............................................................................... 6.44
Checking the Cleaning Function .......................................................................... 6.44
Checking the Dispensing Function ...................................................................... 6.45
Checking the External Instruments Function ......................................................6.45
Printers ..................................................................................................... 6.45