Handleiding voor je Steinel IS 130-2 Bewegingsmelder nodig? Hieronder kun je de handleiding gratis bekijken en downloaden als PDF in het Nederlands en/of Engels. Dit product heeft 0 veelgestelde vragen, 2 comments en heeft 5 stemmen met een gemiddelde score van 20/100. Is dit niet de handleiding die je zoekt, neem dan contact met ons op.

Is je product kapot en biedt de handleiding geen oplossing meer? Dan kun je voor reparatie gratis terecht bij Repair Café.

Handleiding

Loading…

321
110018691 02/2012_C
IS 130-2
i
Principle
Movement triggers lights, alarms and many other devices - for your convenience and safety. The integrated
pyroelectric infrared detector senses the invisible heat radiated from moving objects (people, animals, etc.).
The heat detected in this way is converted electronically into a signal that activates the load connected. Heat
radiation is not detected through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings
During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first
and use a voltage tester to check that the power supply is disconnected.
Installing this unit involves work on the mains voltage supply. This must therefore be carried out
in accordance with applicable national wiring regulations and electrical operating conditions.
(
D
- VDE 0100,
A
-ÖVE-ÖNORM E8001-1,
-SEV 1000)
Only use genuine replacement parts.
Do not dismantle the unit yourself. It must only be repaired by a specialist workshop.
Installation
L = live conductor (usually black or brown)
Connection with concealed wiring
N = neutral conductor (usually blue)
Connection with exposed wiring
PE = any protective earth conductor (green/yellow)
Attention: Loop the protective-earth conductor through if necessary. A mains power switch for turning the unit
ON and OFF may of course be installed in the mains supply lead. Important: Reversing the connections may
result in damage to the unit. Please note that the circuit must be protected by a 10 A circuit breaker.
Minimum installation height: 1.70 m.
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity of all connected
ballasts below the value specified) operating on 230 V AC.
Function
Twilight setting (factory setting: daylight operation at 2000 lux):
The sensor's response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to = daylight operation at approx. 2000 lux.
Control dial set to = night-time operation at approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be set to (daylight operation).
Time setting (factory setting: 8 sec.): Light 'ON' time can be set from 8 secs. to 35 mins.
Control dial set to – = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, it is recommended to select the shortest time –.
Adjust detection zone at swivel mount
Reach 2 – 12 m, by tilting sensor lens through 90°.
Using adhesive shrouds, e.g. to mask out paths or neighbouring properties.
Important: The most reliable way of detecting motion is to install the SensorLight with the sensor aimed across
the direction in which a person would walk and by ensuring that no obstacles (such as trees and walls, for
example) obstruct the line of sensor vision. Reach is limited when walking directly towards the light.
Troubleshooting (Fault / Cause
Remedy
)
No power / Fuse faulty, not switched on
new fuse, turn power switch ON, check lead with voltage tester.
Will not switch ON / Surroundings still too bright
wait until response threshold is reached or adjust setting
/
Bulb faulty
change bulb /
Power switch OFF
switch on /
Detection zone not properly targeted
readjust.
Will not switch OFF / Permanent movement in the detection zone
adjust detection zone
. Keeps switching
ON/OFF / There is a light in the detection zone
change detection zone, increase distance
. Switches ON
when unwanted / Detecting cars on the road, for example
change detection zone, tilt sensor down.
Reach changing / Differing ambient temperatures
at low temperatures, shorten reach by tilting sensor
down; at high temperatures, tilt sensor up.
Declaration of conformity
This product complies with Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC and RoHS Directive
2002/95/EC.
Functional warranty
This STEINEL product has been manufactured with great care, tested for proper operation and safety in accordance
with applicable regulations and then subjected to random sample inspection. STEINEL guarantees that it is perfect
condition and proper working order. The warranty period is 36 months, starting from the date of sale to the con-
sumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own discretion. The warranty does not cover damage to wear parts,
nor does it cover damage or defects caused by improper treatment, maintenance or the use on non-genuine parts.
Further consequential damage to other objects shall be excluded. The warranty will only be honoured if the product
is sent to the appropriate Service Centre fully assembled and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's stamp). Service: Our Customer Service Department will repair
faults not covered by warranty or after the warranty period. Please send the product well packed to your
nearest Service Centre.
ENGLISH
GB
18
7
9
8
10
5
6
10
11
Download de handleiding in het Nederlands en/of Engels (PDF, 9.47 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Steinel IS 130-2 Bewegingsmelder. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Steinel. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Steinel IS 130-2 Bewegingsmelder in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Steinel
Model IS 130-2
Categorie Bewegingsmelders
Bestandstype PDF
Bestandsgrootte 9.47 MB

Alle handleidingen voor Steinel Bewegingsmelders
Meer handleidingen voor Bewegingsmelders

Beoordeling

Laat ons weten wat je van de Steinel IS 130-2 Bewegingsmelder vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Steinel IS 130-2 Bewegingsmelder?
Ja Nee
20%
80%
5 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de Steinel IS 130-2 Bewegingsmelder. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Jean Demorieux 23-01-2021
Ik heb zojuist de IS 130-2-sensor aangesloten op het 220 v-netwerk en op de led-projector, waarbij ik de instructies in de montage-instructies in acht heb genomen en ervoor heb gezorgd dat de netwerkdraad aangesloten in positie L inderdaad die van de fase was (226 v ten opzichte van de aarde) Na aansluiting op het lichtnet gaat de projector niet aan!! welke diagnose kan worden afgeleid (positie van de potentiometer op de maan) en mediaanpositie voor de verlichtingsduur

beantwoord | Ik vind dit nuttig (8) (Vertaald door Google)
Tacheau 03-09-2021
Hallo, ik heb maar drie zonen die uit mijn muur komen. Een zwarte, een blauwe en een aarde geelgroen. In vergelijking met uw product mis ik een draad om de paarse kracht te geven. Kun je me meer vertellen. Met vriendelijke groeten

beantwoord | Ik vind dit nuttig (7) (Vertaald door Google)