the suction side of the pump unless it is an isolator valve in a gravity fed system.
It is IMPORTANT to note also, that these pumps should not be operated with the
delivery valve completely closed.
To prevent unnecessary strain or possible distortion to the pump, ensure that
adequate support is provided to the hoses and/or pipes. Remember they will be
considerably heavier when filled with water.
Should sand, chemical or other contaminants come into contact with the pump,
flush through with cold clean water as soon as possible.
Protect the pump and pipework from freezing. The formation of ice may cause
serious damage.
Where the pump is to be a permanent fixture, the fittings to the pump MUST be
flexible, i.e. a short piece of hose should be inserted between rigid metal pipework
and the pump.
It is strongly recommended that in addition to the coarser foot filter, an inlet filter
should be fitted to prevent the possibility of any foreign body from entering the
pump. This is particularly important in the case of multi stage pumps CBM240,
CBM240E & CBM250SS. A filter specifically designed for all pumps in the range is
available from your CLARKE dealer - see Accessories on page 30.
The filter bowl is transparent allowing a visual check as to the condition of the filter
cartridge. The filter cartridge is a washable net type, with a rated filtration of 60
microns, suitable for the efficient removal of suspended particles such as sand.The
filter is NOT designed to filter mud, sludge etc.
CPE100TF, CBM100SS, CBM130SS, CBM250SS and CBM240E.
These pumps are set up as BOOSTER PUMPS, described in greater detail below, and
are provided with non-return valves. Additionally, 100TF & 240E models are provided
with filters, (optional accessories for SS models - see your Clarke dealer for details).
Non-return valves and filters are connected to the inlet port as follows:
Screw the non return valve into the inlet port, ensuring the arrow, stamped on the
valve points inwards towards the inlet port. Tighten the valve, BUT DO NOT
OVERTIGHTEN, then screw the filter on to the valve - again DO NOT OVERTIGHTEN.
The filter should hang vertically when completed.
CBM240E
This pump is set up as a BOOSTER Pump by incorporating the CLARKE EPC 1000
HYDROTRONIC UNIT - a computerised electronic device which automatically
switches the pump ON and OFF whenever a tap, or other restriction in the outlet
side of the pump, such as a spray lance etc., is turned ON or OFF.
Please ensure you are thoroughly familiar with the operation of this device by reading
the enclosed leaflet describing its’ operation and maintenance, before you operate the
pump. It is important to note that in order for the hydrotronic unit to operate correctly, the
maximum head ABOVE THE OUTLET OF THE HYDROTRONIC UNIT, is 14 metres.
i.e. Although the pump is capable of delivering water to a maximum head of 48
metres, the hydrotronic unit will not switch the pump ON if the vertical height
above outlet of the unit is greater than 14 metres.