Cleaning and maintenance
Note:
Please deal with simple issues by referring to the attached "FAQ" before calling a service
person.
Statement: Maintenance or repair work can only be performed by qualified service persons.
Improper methods may cause serious accidents or property damage. Make sure to
unplug the water heater before you intend to open the water heater or repair it.
To clean the outside: Disconnect the power supply before cleaning the water heater. Wipe it
lightly with a piece of wet cloth dipped in a little neutral detergent other than gasoline or other
solutions. Then, wipe it with a piece of dry cloth and keep the shell dry. Do not clean it with
detergent containing abrasives (e.g. toothpaste), acid, chemical solvents (e.g. alcohol) or polish.
To clean the inside: To keep the water heater working efficiently, the heating elements and the
inner tank should be cleaned once every three years. Take care not to damage the protection
coating outside the heating element and inside the inner tank. The magnesium anode rod
should be replaced periodically according to local water quality and the using habits.
To clean the inner tank: Blowdown procedure: disconnect the power supply, turn off the
inlet valve and turn on the relief valve to relieve pressure. When no water comes from it,
turn o all the water outlet valves. Remove the drain hose of the relief valve together with
the double nipple. Then, unscrew the blowdown nut. Connect the drain hose with double
nipple on the blowdown port (put the other end of the drain hose in the sewer inlet). Turn
on any one of the water outlets to conduct blowdown. Clean water coming out of the
drain hose indicates the dirt in the inner tank has been totally discharged. Install all the
components in their original places. Note: the water inlet valve should be turned on several
times to rinse the dirt at the bottom of the inner tank during blowdown.
Precautions during use
To avoid damage, never turn on the power before the inner tank is fully filled with water.
To avoid scalding, adjust the water temperature to an appropriate degree before use. Water
over 50
can result in scalding.
The relief valve should be checked once every two weeks during use. The method: turn the
small handle of the relief valve. It is normal if there is water flowing from it. If not, please
contact local after-sales service center.
The product is a water heater of enclosed type. It can supply hot water to several locations
such as bathroom (bathtub, hand wash basin, shower nozzle) and kitchen.
If the water heater is not to be used for an extended period or if it is to be repaired, please
turn o the inlet valve and turn on the relief valve to relieve pressure. Then, open the water
outlet and blowdown port to drain the water in the inner tank. Before reusing, to avoid injury
or accidents, it is recommended to turn on the hot water valve before turning on the power of
the water heater. In this way you can discharge air in the pipeline. At this time, please do not
smoke or light other open flames near the open valve. Meanwhile, carefully check that all the
components of the water heater are in good condition. It can be put into use after all of these
are confirmed. Note: the other end of the drain hose may not be higher than the pressure relief
hole of the relief valve. The drain hose should be inserted into the floor drain or other places to
facilitate draining.
Please ask a service person to conduct safety examinations regularly. Remove the scale on the
heating element in time. Check the consumption of the magnesium anode rod and replace it
in a timely manner if it is too seriously worn.
1
2
3
4
5
6
Dimension diagram Appearance and components
b1
120
a1
c1
246
175
290
145
185
Note:
the allowed error range of above parameters is +10%.
Model Volume Net weight a1 b2 c1
FCD-JTLD200 200L 58 kg 1220mm 629mm 601mm
FCD-JTLD245 245L 65 kg 1399mm 629mm 601mm
Check valve
Blow-
down
port
Relief valve
Electrical
cabinet 1
Heating
element 1
Magnesium
anode rod 2
Electrical
cabinet 2
Heating
element 2
Magnesium
anode rod 1
Shell
Heat preservation
layer
Enamel inner
tank
Blowdown pipe
Indicator lampIndicator lampIndicator lamp
Indicator lampIndicator lampIndicator lamp
Installation methods
Be sure to have it installed by the installation sta from the after-sales service center of
the manufacturer or a center authorized by them. It adopts floorstanding installation.
Locate the water heater and install all the pipes with a tap water tube (PP-R pipe is
recommended) according to the dimension diagram and the user's requirements.
Mount the relief valve and other accessories according to figure 2. Remember to use
Teflon seal tape to avoid leakage.
To facilitate installation and dismantling of the water heater, it is recommended to fit a
G1/2” flexible nut at the suitable location on the water inlet pipe and outlet pipe separately.
Confirm the positions needing water supply and connect the water inlet pipe, outlet pipes
and tap water pipes to the locations separately.
When installing the water heater, please reserve certain space to facilitate future
maintenance and repair. Fig. 2 is only a reference installation schematic of pipelines. In
specific installations, the actual situation of the user should be considered.
Connection and use of the check valve:
Connect the check valve with G1/2
connection screw according to the arrow on it.
Mount the relief valve on the water heater with position as shown in Fig. 2. Fit the double nipple in the
relief hole of the relief valve and then screw one end of the drain hose onto the double nipple (as shown
on Fig. 3). When the water heater is powered on, a small amount of water may drip out of the drain hose.
This is a normal phenomenon caused by expansion of water inside the water heater. The relief hole must
be kept unblocked.
The drain hose can be cut short or extended as necessary. Connect the other end of the drain hose to
the sewage drain to avoid polluting by splashing. The drain hose connecting the relief valve should be
installed in a continuous downward direction and in a frost-free environment.
Be sure to check and confirm that the tank is fully filled with water, that there is no leakage from any
joints, and that the power supply complies with the requirements before switching on the power.
Check
valve
Blowdown
port
Water outlet
pipe
Relief
valve
Drain hose
Water inlet
pipe
Indicator lampIndicator lampIndicator lamp
Indicator lampIndicator lampIndicator lamp
Special hints
Be sure to disconnect the power supply before performing any maintenance or repair work
on it. Only professionals should be allowed to adjust or repair the water.
Make sure the water heater is fully filled with water before turning on the power. Otherwise
malfunction of the heating element may occur. Please make sure the power socket complies
with applicable national standards and is reliably grounded. Never use the water heater
without reliable earthing.
The water heater is fitted with a relief valve. To ensure safety, please do not change its
installation location and never block its outlet.
When the ambient temperature is under 0
, the piping may be damaged due to freezing
of water in it and cause the water heater to malfunction. So you shall drain the water in the
tank to avoid freezing. If the water heater is not to be used for a period of over 1 month,
please unplug the power cord and drain the water tank.
If the electrical water heater is seriously soaked with water, it must be examined and repaired
by a technician authorized by the manufacturer before it is put into use again.
Scale can be formed in the water tank after long periods of use. Besides, water quality may
change due to ageing of the water pipe. After you wash rice or vegetables with water from
the water heater, please rinse them with clean tap water.
Do not place flammables such as gasoline near the water heater to avoid fire or other
accidents.
Precautions during installation
Make sure the inlet pressure of the tap water is not less
than 0.05MPa.
The electrical water heater shall be installed indoors where
the ambient temperature is over 0
. The pipelines shall
be arranged centralizedly. The location of hot water usage
should not be too far way from the water heater. If the
distance is more than 8 meters, the pipe shall be wrapped
with a heat preservation layer to reduce heat loss.
In selecting the installation location of the water heater,
convenient usage and repairing should be considered.
Besides, it must be installed in a place with a sewer so that
it will not cause damage to facilities nearby or downstairs
when the water tank and/or pipes leak.
Do not confuse the water inlet pipe and outlet pipe. The
relief valve shall be installed in the specified location. No
change is allowed. Its pressure relief hole must be kept
unblocked.
To ensure safety, please use a separate socket (never
use a multifunctional socket) which is reliably grounded
and complies with national standard. Check with an
electroprobe to ensure that the live wire and the neutral
wire are not connected backwards. Do not turn on the
power before ensuring that it is fully filled with water, that
there is no leakage from any joints, and that the power
supply meets the requirements.
Using method
In initial use after installation, it must be fully filled with water before turning on the power.
In first use, as the inner tank is empty, you must turn on the tap and one of the water outlets.
Wait until water comes out continuously from water outlets (it indicates the tank is full) and
then turn o the water outlet.
Check all the joints for leakage. After that, plug in the power cord
After the power is turned on, the upper indicator lamp illuminates and the upper heating
element starts heating. When the temperature of the hot water in the water heater reaches
60
, the upper indicator lamp goes out, the lower indicator lamp illuminates and the
lower heating element starts heating. The water heater continues to work. When the lower
indication lamp goes out, the water heater stops working and the whole water heater
reaches the rated temperature 60
.
The rated temperature of the water heater is 60
. The indicator lamps will illuminate in
heating state. When it reaches the rated temperature, the power will be turned o and the
indicator lamps will go out.
Large amount of water will come out from the drain hose of the relief valve if the pressure of
the tap water is higher than 0.7MPa. This is caused by overly high water pressure. Please call
the after-sales service center. Water or vapor will come from the drain hose of the relief valve
if the temperature of water inside the inner tank exceeds 99
+0
-5
. It is reducing temperature
by relieving pressure as the temperature is too high. Please call the after-sales service center
in this case. Please keep away from the drain hose during use to avoid scalding.
(Fig 1)
(Fig 3)
(Fig 2) For reference only
Relief valve
Unit: mm
Download de handleiding in het Nederlands en/of Engels (PDF, 1.1 MB)
(Denk aan het milieu en print deze handleiding alleen als dat echt noodzakelijk is)

Loading…

Meer over deze handleiding

We begrijpen dat het prettig is om een papieren handleiding te hebben voor je Haier FCD-JTLD200 Boiler. Je kunt de handleiding bij ons altijd downloaden en daarna zelf printen. Indien je graag een originele handleiding wilt hebben, raden we je aan contact op te nemen met Haier. Zij kunnen wellicht nog voorzien in een originele handleiding. Zoek je de handleiding van Haier FCD-JTLD200 Boiler in een andere taal? Kies op de homepage je taal naar keuze en zoek daarna op het modelnummer om te zien of we deze beschikbaar hebben.

Specificaties

Merk Haier
Model FCD-JTLD200
Categorie Boilers
Bestandstype PDF
Bestandsgrootte 1.1 MB

Alle handleidingen voor Haier Boilers
Meer handleidingen voor Boilers

Beoordeling

Laat ons weten wat je van de Haier FCD-JTLD200 Boiler vindt door een beoordeling achter te laten. Wil je je ervaringen met dit product delen of een vraag stellen? Laat dan een bericht achter onderaan de pagina.
Bent u tevreden over de Haier FCD-JTLD200 Boiler?
Ja Nee
Beoordeel dit product als eerste
0 stemmen

Praat mee over dit product

Laat hier weten wat jij vindt van de Haier FCD-JTLD200 Boiler. Als je een vraag hebt, lees dan eerst zorgvuldig de handleiding door. Een handleiding aanvragen kan via ons contactformulier.

Veelgestelde vragen over Haier FCD-JTLD200 Boiler

Ons supportteam zoekt dagelijks naar nuttige productinformatie en antwoorden op veelgestelde vragen. Als er onverhoopt toch een onjuistheid tussen onze veelgestelde vragen staat, laat het ons dan weten via het contactformulier.

Mijn boiler geeft alleen lauw water, hoe kan dat? Geverifieerd

Dit is waarschijnlijk een teken dat de thermostaat defect is. Neem contact op met de fabrikant voor advies.

Ik vind dit nuttig (1036) Lees meer

Heeft het zin om mijn boiler tijdens afwezigheid of vakantie uit te schakelen? Geverifieerd

Veel moderne boilers zijn erg energiezuinig. Bij een afwezigheid of vakantie van korter dan 1 week kost het dan vaak meer om het water weer op te warmen dan om het gedurende die periode warm te houden. Bij erg lange afwezigheid kan het zuiniger zijn de boiler uit te schakelen.

Ik vind dit nuttig (368) Lees meer

Er komt water uit het overdrukventiel, is dat normaal? Geverifieerd

Ja, een boiler is een drukvat. Als de druk te hoog wordt dan zal de boiler dit verlagen door water af te voeren via het overdrukventiel. Degene die de boiler heeft geïnstalleerd zou goede afvoer moeten hebben aangelegd.

Ik vind dit nuttig (359) Lees meer

Waar kan ik mijn boiler het beste plaatsen? Geverifieerd

De boiler kan het beste geplaatst worden in de buurt van het punt waar het meeste warme water gebruikt gaat worden (bijv: badkamer). Zo is er sneller warm water en is er minimaal warmteverlies.

Ik vind dit nuttig (210) Lees meer

Wat is het verschil tussen een boiler en een geiser? Geverifieerd

Een boiler verwarmt het water voordat je het wilt gebruiken in de boiler. Bij een geiser wordt het water slechts verwarmt dat er doorheen stroomt wanneer je de kraan opendraait. Hierdoor kan het warme water bij een boiler op zijn wanneer alle voorraad is verbruikt. Daarnaast is het water dat uit een boiler komt direct warm, waarbij het water uit een geiser eerst koud is.

Ik vind dit nuttig (149) Lees meer
Handleiding Haier FCD-JTLD200 Boiler

Gerelateerde producten

Gerelateerde categorieën